F1350AA06

Curtis Industries
A Division of Powers Holdings, Inc.
www.curtisind.com
Specications subject to change.
Dimensions are shown for
reference purposes only.
General Purpose
F1100/F1150 RFI Filters
14
SINGLE PHASE FILTERS
F1300/F1399 RFI Filters (continued)
Amps A B C D E
2A
3.35
(85,1)
1.81
(46,0)
1.16
(29,5)
2.375
(60,33)
2.78
(70,6)
3A
3.85
(97,8)
2.07
(52,6)
1.16
(29,5)
2.938
(74,63)
3.35
(85,1)
6A
3.85
(97,8)
2.07
(52,6)
1.16
(29,5)
2.938
(74,63)
3.35
(85,1)
10A
3.85
(97,8)
2.07
(52,6)
1.53
(38,9)
2.938
(74,63)
3.35
(85,1)
20A
5.23
(132,8)
3.37
(85,6)
1.53
(38,9)
3.75
(95,25)
4.20
(106.7)
F1399AA (2, 3, 6, 10 and 20Amp) Dimensions
Amps A B C D E
2A
2.07
(52.6)
1.81
(46,0)
1.16
(29,5)
2.375
(60,33)
2.78
(70,6)
3A
2.56
(65,0)
2.07
(52,6)
1.16
(29,5)
2.938
(74,63)
3.35
(85.1)
6A
2.56
(65,0)
2.07
(52,6)
1.16
(29,5)
2.938
(74,63)
3.35
(85.1)
10A
2.56
(65,0)
2.07
(52,6)
1.53
(38,9)
2.938
(74,63)
3.35
(85,1)
F1399BB (2, 3, 6 and 10Amp) Dimensions
Amps A B C D
3A
4.33
(110,0)
2.25
(57,2)
1.28
(32,5)
1.575
(40,0)
6A
4.33
(110,0)
2.25
(57,2)
1.28
(32,5)
1.575
(40,0)
10A
4.33
(110,0)
2.25
(57,2)
1.53
(38,9)
1.575
(40,0)
F1399CA (3, 6 and 10Amp) Dimensions
Amps A B C D E
10A
3.96
(100,6)
2.07
(52,6)
1.53
(38,9)
2.938
(74,63)
3.35
(85,1)
20A
5.34
(135,6)
3.37
(85,6)
1.53
(38,9)
3.75
(95,25)
4.20
(106,7)
F1399DD (10 and 20Amp) Dimensions
6.36(0.25) FASTON TERMINAL
WITH Ø1.78 (0.070) HOLE
(SLOTTED HOLE FOR GROUND)
A
D
E
C
B
WIRE LEADS, 18AWG,
(16AWG FOR 10A).
102(4.0) MIN.
C
B
D
E
A
BLUE
BROWN
BLUE
BROWN
G/Y
#6-32
INSERT
IEC CONNECTOR
6.35(0.25) FASTON TERMINAL,
WITH Ø1.78(0.070) HOLE
(SLOTTED HOLE FOR GROUND)
C
B
D
A
16.0
(0.63)
E
D
B
A
C
#8-32 SCREW
TERMINAL
C
B
E
#8-32 SCREW
TERMINAL
50.8 (2.00)
SLOTTED HOLE,
6.4(.25)X4.0(.16)
AD
LINE
LOAD
F1399 Simplied Schematic
Curtis Industries
A Division of Powers Holdings, Inc.
www.curtisind.com
Specications subject to change.
Dimensions are shown for
reference purposes only.
40
SINGLE PHASE FILTERS
Standard Mounting Cutouts
F1200CA, F1300CA, F1400CA,
F1500CA, F1600CA, F1700CA
F1500FA, F1600FA,
1.145
(29,08)
1.417
(36,0)
1.275
(32,39)
.09 R
(2,29)
.638
(16,21)
.140 Dia.
(3,55)
2 Holes
1.20
(30.5)
.90
(22,9)
1.575
(40,0)
.187
(4,75)
.450
(11,43)
.234
(5,94)
.140 Dia.
(3,55)
2 Holes
F1300CP, F1600CP
.062 Hole Dia.
(1,57)
5 Holes
1.500
(38,1)
.600
(15,2)
.700
(17,8)
1.400
(35,6)
N
L
F5500/5600/5700 SERIES
.140 Dia.
(3,55)
2 Holes
.234 R.
(5,94)
(Typ.)
1.575
(40,01)
1.20
(30,48)
.90
(22,8)
for mounting
from back side
SERIES
PE = Power Entry
PM = Medical
Power Entry
LOAD
TERMINATION
A = Quick Connects
B = Wire Leads
D = Screw Terminals
(20 & 30 amp only)
P = Printed Circuit Pins
S = Solder Tab
LINE TERMINATION
A = Quick Connects
B = Wire Leads
C = IEC Connector
D = Screw Terminals
(20 & 30 amp only)
F = Fused IEC
P = Printed Circuit Pins
W = Dual Fused IEC
J = Switched IEC
How to Order
The Curtis part numbering system is made up of four
elements. Each element denotes a specic requirement
(mechanical or electrical) which, when properly
sequenced, fully identies the required catalog lter. As
shown, the rst ve alpha/numeric characters denote
the series type; the sixth character (alpha) denotes the
type of line termination; the seventh character (alpha)
denotes the type of load termination; the last two
characters (numeric) denote the current rating.
Compose your part number as follows: Select the series
required, add two alpha character for the line and load
termination, followed by two numeric characters for
the required current rating. For example, F1100AB06
completely identies an F1100 series lter with quick
connects on line side and wire leads on load side, with
a 6-amp rating.
F1100 X X X
CURRENT
RATING
01 = 1 Amp
03 = 3 Amps
06 = 6 Amps
10 = 10 Amps
15 = 15 Amps
20 = 20 Amps
30 = 30 Amps

F1350AA06

Mfr. #:
Manufacturer:
Description:
LINE FILTER 250VAC 6A CHASS MNT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet