AHK22124

HK (AHK)
ORDERING INFORMATION
Relay for control panel of
1c 15A, and 2c 10A
HK RELAYS (AHK)
FEATURES
1. Economical prices achieved
To assist rationalization, prices reduced
to about half the price of previous
products.
2. Compact with high-capacity
Enables high-capacity control:
15 A for 1 Form C, 10 A for 2 Form C
3. Types for wide range of applications
Range includes relays with operation
indicators, built-in diodes to absorb relay
coil surge, and built-in CR circuits.
4. Sockets and terminal sockets are
available.
TYPICAL APPLICATIONS
Control panels
Power supply units
Molding machines
Machine tools
Welding equipment
Agricultural equipment
Office equipment
Vending machines
Communications equipment
Amusement machines, etc.
HK relays
Contact arrangement
1: 1 Form C
2: 2 Form C
AHK
Terminal arrangement
1: AC plug-in type
2: DC plug-in type
Nominal coil voltage
06:
X0:
X1:
Y0:
Y2:
6, 12: 12, 24: 24, 48: 48 V
100/110 V AC, 100/110 V DC
110/120 V AC
200/220 V AC
220/240 V AC
Type classification
0: Standard
1: With LED indication
2: With diode
3: With LED indication and diode
4: With CR circuit
5: With LED indication and CR circuit
Note: Certified by UL/C-UL and TÜV
ASCTB113E 201209-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
RoHS compliant
HK (AHK)
TYPES
* For sockets and terminal sockets, see page 100.
RATING
1. Coil data
1) AC coils
Notes: 1. The relay operates in a range of 80% to 110 % V of the nominal coil voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at
the nominal coil voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the nominal coil voltage, humming will occur and a
large current will flow leading possibly to coil burnout.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
Nominal coil voltage
Nominal coil current,
mA
Nominal operating power,
V A
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Inductance, H
Max. applied
voltage
50Hz 60Hz 50Hz 60Hz
When
drop-out
When
operating
12V AC 111 100
1.3 1.2
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
0.312 0.295
110%V of
nominal voltage
24V AC 56 50 1.243 1.181
48V AC 28 25 4.974 4.145
100/110V AC 13.4/14.7 12/13.2 23.75 20.63
110/120V AC 12.2/13.5 10.9/11.9 27.19 25.57
200/220V AC 6.7/7.4 6/6.6 85.98 81.76
1. Plug-in type
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2. Plug-in type (with LED indication)
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Nominal coil voltage
1 Form C 2 Form C
Part No. Part No.
6V DC AHK12006 AHK22006
12V DC AHK12012 AHK22012
24V DC AHK12024 AHK22024
48V DC AHK12048 AHK22048
100/110V DC AHK120X0 AHK220X0
12V AC AHK11012 AHK21012
24V AC AHK11024 AHK21024
48V AC AHK11048 AHK21048
100/110V AC AHK110X0 AHK210X0
110/120V AC AHK110X1 AHK210X1
200/220V AC AHK110Y0 AHK210Y0
220/240V AC AHK110Y2 AHK210Y2
Nominal coil voltage
1 Form C 2 Form C
Part No. Part No.
6V DC AHK12106 AHK22106
12V DC AHK12112 AHK22112
24V DC AHK12124 AHK22124
48V DC AHK12148 AHK22148
100/110V DC AHK121X0 AHK221X0
12V AC AHK11112 AHK21112
24V AC AHK11124 AHK21124
48V AC AHK11148 AHK21148
100/110V AC AHK111X0 AHK211X0
110/120V AC AHK111X1 AHK211X1
200/220V AC AHK111Y0 AHK211Y0
220/240V AC AHK111Y2 AHK211Y2
3. Plug-in type (with diode)
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
4. Plug-in type (with diode and LED indication)
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Nominal coil voltage
1 Form C 2 Form C
Part No. Part No.
6V DC AHK12206 AHK22206
12V DC AHK12212 AHK22212
24V DC AHK12224 AHK22224
48V DC AHK12248 AHK22248
100/110V DC AHK122X0 AHK222X0
Nominal coil voltage
1 Form C 2 Form C
Part No. Part No.
6V DC AHK12306 AHK22306
12V DC AHK12312 AHK22312
24V DC AHK12324 AHK22324
48V DC AHK12348 AHK22348
100/110V DC AHK123X0 AHK223X0
5. Plug-in type (with CR circuit)
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
6. Plug-in type (with CR circuit and LED indication)
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Nominal coil voltage
1 Form C 2 Form C
Part No. Part No.
100/110V AC AHK114X0 AHK214X0
110/120V AC AHK114X1 AHK214X1
200/220V AC AHK114Y0 AHK214Y0
220/240V AC AHK114Y2 AHK214Y2
Nominal coil voltage
1 Form C 2 Form C
Part No. Part No.
100/110V AC AHK115X0 AHK215X0
110/120V AC AHK115X1 AHK215X1
200/220V AC AHK115Y0 AHK215Y0
220/240V AC AHK115Y2 AHK215Y2
ASCTB113E 201209-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
HK (AHK)
2) DC coils (at 20°C 68°F)
Notes: 1. The rated excitation current is ±10% (20°C 68°F).
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
3. The relay operates in a range of 80% to 110 % V of the nominal coil voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at
the nominal coil voltage.
4. For use with 200 V DC, connect a 10 K (5W) resistor, in series, to the 100 V DC relay.
5. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2. Specifications
Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature
between –50°C to +40°C –58°F to +104°F (AC type).
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
Nominal coil voltage
Nominal coil current,
mA
Nominal operating
power, W
Coil resistance,
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. applied voltage
(at 70°C 158°F)
6V DC 150
0.9
40
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
12V DC 75 160
24V DC 37 650
48V DC 18.5 2,600
100/110V DC 10 1.0 10,000
Characteristics Item Specifications
Contact
Contact resistance (Initial) Max. 50 m (By voltage drop 6 V DC 1A)
Contact material AgSnO
2 type
Rating
Nominal switching capacity 1 Form C: 15A 125V AC (resistive load), 2 Form C: 10A 125V AC (resistive load)
Max. switching voltage 250V AC, 125V DC
Max. switching current 15A (1 Form C), 10A (2 Form C)
Min. switching capacity (Reference value)*
1
100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 100M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact sets 2,000 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil 2,000 Vrms for 1min. (Detection current: 10mA.)
Temperature rise (coil) Max. 80°C 176°F (By resistive method, nominal voltage)
Operate time (at 20°C 68°F)*
2
Max. 25ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time (at 20°C 68°F)*
2
Max. 25ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 196 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 2 mm
Expected life
Mechanical AC type: 5×10
7
(at 180 times/min.), DC type: 10
8
(at 180 times/min.)
Electrical AC load
1 Form C: 15A 125V AC (resistive load) (cosϕ=1), Min. 2×10
5
2 Form C: 10A 125V AC (resistive load) (cosϕ=1), Min. 5×10
5
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature:
–50°C to +70°C –58°F to +158°F (Without LED indication);
–50°C to +60°C –58°F to +140°F (With LED indication)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. Operating speed 20 times/min. (at max. rating)
Unit weight Approx. 35g 1.23 oz
ASCTB113E 201209-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e

AHK22124

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
General Purpose Relays 2 Form C, 24VDC with LED 24VDC Coil
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet