www.honeywell.com/sensing/products/di
M
ODELS
LT
•
HALF
INCH
DIAMETER
LINEAR
POSITION
TRANSDUCER
TECHNICAL SPECIFICATIONS
Sensing and Control
Honeywell
100 Discovery Way
Acton, MA 01720 USA
Tel: (877) 384-1300; Fax: (978) 263-0630
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local
sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell
will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of merchantability and fitness for a particular purpose.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer
to determine the suitability of the product in the application.
Item # 1124800 M.G. 10/01
DIMENSIONS
xx.xx = inches
(xx.x) = mm
MECHANICAL
Total Mechanical Travel 1.05 to 10.05 in. (min)
26.7 to 255.3 mm (min)
Starting Force 1.0 oz (max)*
Shock 50 g 11 ms half sine
Vibration 20 g rms 5 Hz to 2 KHz
Life One Billion dither operations
ELECTRICAL
Electrical Travel 1 to 10 in.
(1 inch increments) (25.4 to 254.0 mm)
Independent Linearity ** ±1.0%
Total Resistance 1000 Ohms per inch
electrical travel
Resistance Tolerance ±20%
Operating Temperature -40° to 80°C
(-40° to 176°F)
Resolution Infinite
Insulation Resistance 500 M Ohms @ 500 Vdc
Dielectric Strength 1000 V rms
Max. Applied Voltage 30 Vdc
Backlash 0.0002 in. max
Recommended Wiper Current <1 µA
* 12 oz. max. for ‘LTW’ models rated at IPX5
** From 5% to 95% of theoretical electrical travel
Caution: Do not test on an Ohm Meter on the Rx 1 scale or other current devices.
Caution: Excessive Wiper Current can cause Output errors or damage.
Caution: Zero shaft side load is recommended to achieve maximum life.
(Retracted)
#4-40 UNC-2A
Thd x .50
12.7
Lon
1" [25.4]
#28 Jacketed Cable
6.0 (152.4) Long Min
¯1/2"
[12.7]
¯1/8" [3.17]
Housing Length 'X'
(Electrical Travel +1.50 [38.1])
(Red)
V-in
Shaft
Extended
(Black)
Ground
(Brown)
V-out
Connect to High Impedance Circuit
SPECIALS AND ACCESSORIES
• Other Mechanical Travels
• Other Electrical Travels
• Other Resistance Values
• Rod-end Bearing
• Metric Shaft Adapter
Model Electrical Travel Total Resistance Housing Length Weight
in inches Ohms ‘X’ in inches in grams
LTS01 or LTW01 1.0 1000 2.5 20
LTS02 or LTW02 2.0 2000 3.5 26
LTS03 or LTW03 3.0 3000 4.5 31
LTS04 or LTW04 4.0 4000 5.5 43
LTS05 or LTW05 5.0 5000 6.5 45
LTS06 or LTW06 6.0 6000 7.5 48
LTS07 or LTW07 7.0 7000 8.5 51
LTS08 or LTW08 8.0 8000 9.5 57
LTS09 or LTW09 9.0 9000 10.5 62
LTS10 or LTW10 10.0 10000 11.5 68