6W AC-DC Reliable Industrial Adaptor
GS06U series
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.)
Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
PROTECTION
5V
7.5V 9V 12V 15V 18V 24V 48V
GS06U-1 GS06U-1-1
GS06U-1P1J GS06U-11P1J GS06U-2P1J GS06U-3P1J GS06U-4P1J GS06U-5P1J GS06U-6P1J GS06U-8P1J
GS06U-2 GS06U-3 GS06U-4 GS06U-5 GS06U-6 GS06U-8
1.00A 0.8A 0.66A 0.5A 0.4A 0.33A 0.25A 0.125A
0 ~ 1.00A 0 ~ 0.8A 0 ~ 0.66A 0 ~ 0.5A 0 ~ 0.4A 0 ~ 0.33A 0 ~ 0.25A 0 ~ 0.125A
5W
6W 6W 6W 6W 6W 6W 6W
50mVp-p 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 180mVp-p 200mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0%
±5.0%
±5.0%
±5.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±3.0%
±3.0%
±3.0%
±2.0%
±2.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0%
±2.0%
1000ms, 50ms, 12ms at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
75%
80.5% 79.5% 79.5% 80.5% 81.5% 82% 85%
0.2A / 100VAC
Cold start 30A/ 115VAC 50A / 230VAC
0.25mA / 240VAC
UL60950-1, CSA C22.2, approved
EAC TP TC 004
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
500Khrs min. MIL-HDBK-217F(25 )℃
0 ~ +50 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
32*66*42.5mm (L*W*H)
100g ; 110pcs / 12Kg / CARTON
CONNECTOR
PLUG
CABLE
See page 4 5 ; Other type available by customer requested~
See page 4 5 ; Other type available by customer requested~
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor. μμ
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load.
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
OVERLOAD
OVER VOLTAGE
>105% rated output power for 5V ; >110% rated output power for 7.5 ~ 48V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
>120% rated output voltage
Protection type : Clamp by zener diode
SAFETY &
EMC
(Note. 7)
EMC EMISSION
Parameter
Standard
FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
Test Level / Note
Class B
Class B
FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
Conducted emission
Radiated emission
File Name:GS06U-SPEC 2018-03-27