GP50A series
50W AC-DC Triple Output Industrial Adaptor
SPECIFICATION
GP50A13A-R1B GP50A13D-R1B GP50A14E-R1B
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
CURRENT RANGE
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
PROTECTION
5V
GP50A13A GP50A13D GP50A14E
12V 5V 12V 5V 15V
4A 2A 4A 2A 4A 1.5A
0 ~ 4.0A 0.3 ~ 2.0A 0 ~ 4.0A 0.3 ~2.0A 0 ~ 4.0A 0.3 ~ 1.5A
RATED POWER
1000ms, 50ms, 20ms / 230VAC 1500ms, 50ms, 16ms / 115VAC at full load
90 ~ 264VAC 135~ 370VDC
47 ~ 63Hz
1.6A / 100VAC 0.8A / 230VAC
84% 84% 84.5%
Cold start 30A/115VAC 45A / 230VAC
0.75mA / 240VAC
UL60950-1, CSA22.2, EN60950-1, approved
EAC TP TC 004
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC , I/P-FG:2121VDC
I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
280K hrs min. MIL-HDBK-217F (25 )℃
-20 ~ +70 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
146*75.5*43mm (L*W*H)
0.55kg; 36pcs / 21kg / CARTON
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor. μμ
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.When measured between the light load (20% of rated load) and full load, the load regulation is within 5% whereas the cross regulation is within 15%.±±
7.Derating may be needed under low input voltages. Please check the static characteristics for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
3 years : 100% load 40 , 8hours day℃/
CONNECTOR
PLUG
CABLE
See page 4
See page 4
-5V
0.5A
0.1 ~ 0.5A
-12V
0.5A
0.1 ~0.5A
-15V
0.5A
0.1 ~ 0.5A
RIPPLE & NOISE (max.)
Note.3 50mVp-p
46.5W 50W 50W
100mVp-p 50mVp-p 150mVp-p 50mVp-p 150mVp-p100mVp-p 100mVp-p 150mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±3.0% ±5.0% ±3.0% ±5.0% ±3.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±3.0% ±5.0% ±3.0% ±5.0% ±3.0%
-5% ~ +10%
±1.0%
±5.0%
-5% ~ +8%
±1.0%
±5.0%
-5% ~ +15%
±1.0%
±5.0%
120 ~ 200% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode, output short
LIFE
RATED SET CURRENT
SAFETY &
EMC
(Note. 8)
EMC IMMUNITY
EMC EMISSION
Parameter
Standard
EN61000-3-2
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-11
>.95% dip 0 5 periods, 30% dip 25 periods,
95% interruptions 250 periods>
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
EFT bursts
Surge susceptibility
Level 3, 8KV air; Level 2, 4KV contact
Conducted susceptibility
Level 2, 3V/m
Level 2, 3V
Level 2, 1KV
RF field
susceptibility
Voltage dips , interruption
File Name:GP50A-SPEC 2018-01-15
EN55032(CISPR32),FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
EN55032(CISPR32),FCC PART 15 / CISPR22, CAN ICES-3(B)/NMB-3(B)
Level 3, 1KV/L-N, 2KV/L,N-PE