LTC3526/LTC3526B
7
3526bfd
3
+
+
GATE DRIVERS
AND
ANTI-CROSS
CONDUCTION
LOGIC
CLK
I
PK
I
PK
COMP
SLOPE
COMP
I
ZERO
COMP
ERROR AMP
SLEEP COMP
I
ZERO
WAKE
EXPOSED
PAD
+
WELL
SWITCH
MODE
CONTROL
UVLO
V
REF
V
REF
4M
SHDN
V
BEST
START-UP
1MHz
OSC
TSD
THERMAL
SHUTDOWN
SHUTDOWN
ANTI-RING
V
SEL
V
IN
1
6
SW
V
OUT
L1
4.7µH
V
B
SHUTDOWN
CLAMP
C
SS
V
REF
V
OUT
5
7
GND
3526 BD
2
FB
R2
C
OUT
4.7µF
V
OUT
1.6V
TO 5.25V
R1
4
C
IN
2.2µF
V
IN
0.85V
TO 5V
block Diagram
(Refer to Block Diagram)
operaTion
The LTC3526/LTC3526B are 1MHz synchronous boost
converters housed in a 6-lead 2mm × 2mm DFN package.
With the ability to start up and operate from inputs less
than 1V, these devices feature fixed frequency, current
mode PWM control for exceptional line and load regula-
tion. The current mode architecture with adaptive slope
compensation provides excellent transient load response,
requiring minimal output filtering. Internal soft-start and
internal loop compensation simplifies the design process
while minimizing the number of external components.
With its low R
DS(ON)
and low gate charge internal N-chan-
nel MOSFET switch and P-channel MOSFET synchronous
rectifier, the LTC3526 achieves high efficiency over a wide
range of load currents. Automatic Burst Mode operation
maintains high efficiency at very light loads, reducing
the quiescent current to just 9µA. Operation can be best
understood by referring to the Block Diagram.
L
OW
VOLTAGE START-UP
The LTC3526/LTC3526B include an independent start-up
oscillator designed to start up at an input voltage of 0.85V
(typical). Soft-start and inrush current limiting are provided
during start-up, as well as normal mode.
When either V
IN
or V
OUT
exceeds 1.4V typical, the IC
enters normal operating mode. When the output voltage
LTC3526/LTC3526B
8
3526bfd
Error Amplifier
The positive input of the transconductance error amplifier
is internally connected to the 1.195V reference and the
negative input is connected to FB. Clamps limit the mini-
mum and maximum error amp output voltage for improved
large-signal transient response. Power converter control
loop compensation is provided internally. An external
resistive voltage divider from V
OUT
to ground programs
the output voltage via FB from 1.6V to 5.25V.
V V
R
R
OUT
= +
1 195 1
2
1
.
Current Sensing
Lossless current sensing converts the peak current signal of
the N-channel MOSFET switch into a voltage that is summed
with the internal slope compensation. The summed signal
is compared to the error amplifier output to provide a peak
current control command for the PWM.
Current Limit
The current limit comparator shuts off the N-channel
MOSFET switch once its threshold is reached. The cur-
rent limit comparator delay to output is typically 60ns.
Peak switch current is limited to approximately 700mA,
independent of input or output voltage, unless V
OUT
falls
below 0.7V, in which case the current limit is cut in half.
Zero Current Comparator
The zero current comparator monitors the inductor cur-
rent to the output and shuts off the synchronous rectifier
(Refer to Block Diagram)
operaTion
ZETEX ZC2811E
3526 F01
LTC3526/LTC3526B
SHDN
V
IN
V
CNTRL
4M
±30%
LTC3526/LTC3526B
SHDN
4M
±30%
1M
R
V
CNTRL
1M
R > (V
CNTRL
/(V
IN
+ 0.4) – 1)MΩ
Figure 1. Recommended Shutdown Circuits when Driving
SHDN above V
IN
exceeds the input by 0.24V, the IC powers itself from
V
OUT
instead of V
IN
. At this point the internal circuitry has
no dependency on the V
IN
input voltage, eliminating the
requirement for a large input capacitor. The input voltage
can drop as low as 0.5V. The limiting factor for the ap-
plication becomes the availability of the power source to
supply sufficient energy to the output at low voltages, and
maximum duty cycle, which is clamped at 90% typical.
Note that at low input voltages, small voltage drops due
to series resistance become critical, and greatly limit the
power delivery capability of the converter.
L
OW
NOISE FIXED FREQUENCY OPERATION
Soft-Start
The LTC3526/LTC3526B contain internal circuitry to provide
soft-start operation. The soft-start circuitry slowly ramps
the peak inductor current from zero to its peak value of
700mA (typical) in approximately 0.5ms, allowing start-
up into heavy loads. The soft-start circuitry is reset in the
event of a shutdown command or a thermal shutdown.
Oscillator
An internal oscillator sets the switching frequency to
1MHz.
Shutdown
Shutdown is accomplished by pulling the SHDN pin
below 0.3V and enabled by pulling the SHDN pin above
0.8V typical. Although SHDN can be driven above V
IN
or V
OUT
(up to the absolute maximum rating) without
damage, the LTC3526/LTC3526B have a proprietary test
mode that may be engaged if SHDN is held in the range
of 0.5V to 1V higher than the greater of V
IN
or V
OUT
. If
the test mode is engaged, normal PWM switching action
is interrupted, which can cause undesirable operation
in some applications. Therefore, in applications where
SHDN may be driven above V
IN
, a resistor divider or other
means must be employed to keep the SHDN voltage below
(V
IN
+ 0.4V) to prevent the possibility of the test mode
being engaged. Please refer to Figure 1 for two possible
implementations.
LTC3526/LTC3526B
9
3526bfd
when this current reduces to approximately 30mA. This
prevents the inductor current from reversing in polarity,
improving efficiency at light loads.
Synchronous Rectifier
To control inrush current and to prevent the inductor
current from running away when V
OUT
is close to V
IN
, the
P-channel MOSFET synchronous rectifier is only enabled
when V
OUT
> (V
IN
+ 0.24V).
Anti-Ringing Control
The anti-ringing control connects a resistor across the
inductor to prevent high frequency ringing on the SW pin
during discontinuous current mode operation. Although
the ringing of the resonant circuit formed by L and C
SW
(capacitance on SW pin) is low energy, it can cause EMI
radiation.
Output Disconnect
The LTC3526/LTC3526B are designed to allow true output
disconnect by eliminating body diode conduction of the
internal P-channel MOSFET rectifier. This allows for V
OUT
to go to zero volts during shutdown, drawing no current
from the input source. It also allows for inrush current
limiting at turn-on, minimizing surge currents seen by the
input supply. Note that to obtain the advantages of output
disconnect, there must not be an external Schottky diode
connected between the SW pin and V
OUT
. The output dis-
connect feature also allows V
OUT
to be pulled high, without
any reverse current into a battery connected to V
IN
.
Thermal Shutdown
If the die temperature exceeds 160°C, the LTC3526/
LTC3526B will go into thermal shutdown. All switches
will be off and the soft-start capacitor will be discharged.
The device will be enabled again when the die temperature
drops by about 15°C.
Burst Mode OPERATION
The LTC3526 will automatically enter Burst Mode opera-
tion at light load and return to fixed frequency PWM mode
when the load increases. Refer to the Typical Performance
Characteristics to see the output load Burst Mode thresh-
old current vs V
IN
. The load current at which Burst Mode
operation is entered can be changed by adjusting the
inductor value. Raising the inductor value will lower the
load current at which Burst Mode operation is entered.
In Burst Mode operation, the LTC3526 still switches at a
fixed frequency of 1MHz, using the same error amplifier
and loop compensation for peak current mode control.
This control method eliminates any output transient
when switching between modes. In Burst Mode opera-
tion, energy is delivered to the output until it reaches the
nominal regulation value, then the LTC3526 transitions to
sleep mode where the outputs are off and the LTC3526
consumes only 9µA of quiescent current from V
OUT
. When
the output voltage droops slightly, switching resumes.
This maximizes efficiency at very light loads by minimizing
switching and quiescent losses. Burst Mode output voltage
ripple, which is typically 1% peak-to-peak, can be reduced
by using more output capacitance (10µF or greater), or
with a small capacitor (10pF to 50pF) connected between
V
OUT
and FB.
As the load current increases, the LTC3526 will automati-
cally leave Burst Mode operation. Note that larger output
capacitor values may cause this transition to occur at lighter
loads. Once the LTC3526 has left Burst Mode operation and
returned to normal operation, it will remain there until the
output load is reduced below the burst threshold.
Burst Mode operation is inhibited during start-up and soft-
start and until V
OUT
is at least 0.24V greater than V
IN
.
The LTC3526B features continuous PWM operation at
1MHz. At very light loads, the LTC3526B will exhibit
pulse-skip operation.
(Refer to Block Diagram)
operaTion

LTC3526EDC#TRMPBF

Mfr. #:
Manufacturer:
Analog Devices / Linear Technology
Description:
Switching Voltage Regulators 500mA Low Vout Synchronous Boost w/disconnect
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union