Surge arrester B88069X8300****
3-electrode arrester T83-A90X
PPD AB PD / PPD AB PM 2015-09-25
Please read Cautions and warnings and Page 2 of 6
Important notes at the end of this document.
Features Applications
Fast response time
High current rating
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
Telecommunications
Line protection
Base station protection
Electrical specifications
DC spark-over voltage
1) 2) 3)
90
20
V
%
Impulse spark-over voltage
3)
at 100 V/µs - for 99% of measured values
- typical values of distribution
at 1 kV/µs - for 99% of measured values
- typical values of distribution
< 400
< 300
< 550
< 500
V
V
V
V
Service life
10 operations 50 Hz; 1 s
4)
10 A
1 operation 50 Hz; 0.18 s (9 cycl.)
4)
40 A
10 operations [5× (+) & 5× (–)] 8/20 µs
4)
10 kA
1 operation 8/20 µs
4)
15 kA
1 operation 10/350 µs
4)
2 kA
300 operations [150× (+) & 150× (–)] 10/1000 µs
4)
200 A
Insulation resistance at 50 V
DC
3)
> 10
G
Capacitance at 1 MHz
3)
< 1.5 pF
Transverse delay time
5)
< 0.2 µs
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 15
< 0.5
~ 70
V
A
V
Weight ~ 2 g
Operation and storage temperature
40 ... +90
°C
Climatic category (IEC 60068-1) 40/090/21
Marking, blue negative
90 YY O
90 - Nominal voltage
YY - Year of production
O - Non radioactive
Certifications UL 497B (E163070)
Remarks on next page