Table R5 - Physical Characteristics and Environmental Specifications for Radial-leaded Devices
UL File # E74889
CSA File # CA78165C
TÜV Certificate number available on request (per IEC 60730-1).
Agency Recognitions for Radial-leaded Devices
Table R6 - Packaging and Marking Information for Radial-leaded Devices
Cont'd
...
Part Number Bag Quantity Tape & Reel Quantity Ammo Pack Quantity Standard Pack Quantity Part Marking Agency Recognition
LVR 240V
AC
/LVRL 120V
AC
LVR005K 500 — — 10,000 L005 UL,CSA, TÜV
LVR005K-2 — 2,000 — 10,000 L005 UL,CSA, TÜV
LVR005S 500 — — 10,000 L005 UL,CSA, TÜV
LVR005S-2 — 2,000 — 10,000 L005 UL,CSA, TÜV
LVR008K 500 — — 10,000 L008 UL,CSA, TÜV
LVR008K-2 — 2,000 — 10,000 L008 UL,CSA, TÜV
LVR008S 500 — — 10,000 L008 UL,CSA, TÜV
LVR008S-2 — 2,000 — 10,000 L008 UL,CSA, TÜV
LVR012K 500 — — 10,000 L012 UL,CSA, TÜV
LVR012K-2 — 2,000 — 10,000 L012 UL,CSA, TÜV
LVR012S 500 — — 10,000 L012 UL,CSA, TÜV
LVR012S-2 — 2,000 — 10,000 L012 UL,CSA, TÜV
LVR016K 500 — — 10,000 L016 UL,CSA, TÜV
LVR016K-2 — 2,000 — 10,000 L016 UL,CSA, TÜV
LVR016S 500 — — 10,000 L016 UL,CSA, TÜV
LVR016S-2 — 2,000 — 10,000 L016 UL,CSA, TÜV
LVR025K 500 — — 10,000 L025 UL,CSA, TÜV
LVR025K-2 — 2,000 — 10,000 L025 UL,CSA, TÜV
LVR025S 500 — — 10,000 L025 UL,CSA, TÜV
LVR025S-2 — 2,000 — 10,000 L025 UL,CSA, TÜV
RGEF
Environmental Specifications
Test Conditions Resistance Change
Passive aging -40°C, 1000 hours ±5%
85°C, 1000 hours ±5%
Humidity aging 85°C, 85%RH, 1000 hours ±5%
Thermal Shock 85°C, -40°C (10 times) ±5%
Solvent resistance MIL-STD-202, Method 215F No change
RHEF
Physical Characteristics
Lead material RHEF050 to RHEF200: Tin-plated copper clad steel, 0.205mm
2
(24AWG), ø0.51mm/0.020in.
RHEF300 to RHEF1100: Tin-plated copper, 0.52mm
2
(20AWG), ø0.81mm/0.032in.
RHEF1300 to RHEF1500: Tin-plated copper, 0.82mm
2
(18AWG), ø1.0mm/0.04in.
Soldering characteristics Solderability pre ANSI/J-STD-002 Category 3
Solder heat withstand per IEC 68-2-20, Test Tb, Method 1a, condition b; can withstand 10 seconds at 260°C ±5°C
Insulting material Cured, flame-retardant epoxy polymer; meets UL 94V-0
Devices are not designed to be placed through a reflow process.
RHEF
Environmental Specifications
Test Conditions Resistance Change
Passive aging 70°C, 1000 hours ±5%
85°C, 1000 hours ±5%
Humidity aging 85°C, 85%RH, 1000 hours ±5%
Thermal Shock 125°C, -40°C (10 times) ±5%
Solvent resistance MIL-STD-202, Method 215F No change
Devices are not designed to be placed through a reflow process.
Notes: Storage conditions: 40°Cmax., 70% RH max.; devices should remain in original sealed bags prior to use. Devices may not meet specificed values
if these storage conditions are exceeded.
For the TR devices series, see the Telecommunications and Networking section.
Radial-leaded Devices