SACC-M12MSD-4CON-PG 9-SH Order No.: 1521261
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1521261
PHOENIX CONTACT Inc., USA Page 2 / 4
http://www.phoenixcon.com Jan 6, 2011
Insulation resistance ≥ 100 MΩ
Ambient temperature (operation) -40 °C ... 85 °C (Male connector / female connector)
General characteristics
Standards/regulations M12 connector IEC 61076-2-101
Coding D - data
Surge voltage category II
Pollution degree 3
Degree of protection IP67
Insertion/withdrawal cycles ≥ 100
Contact material CuZn
Contact surface material Au
Contact carrier material PA 66
Material of grip body Zinc die-cast, nickel-plated
Material, knurls Nickel-plated brass
Sealing material NBR
Type of connection Screw connection
Conductor cross section stranded min. 0.25 mm²
Conductor cross section stranded max. 0.75 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 18
External cable diameter 6 mm ... 8 mm
Status display No
Conductor data
Transmission characteristics (category) CAT5 (IEC 11801:2002), CAT5e (TIA 568B:2001)
Diagrams/Drawings
Functional drawing
Assembly steps for M12 male/female connector and
conductor
a = Slide on parts
b= Strip conductor, widen shield and lay around the shielding
ring, cut off projecting mesh. Slide cores through the housing.
Mount shielding ring, gasket and clamping cage. Tighten
pressure screw to fix the cable. Screw down cores. Mount
male/female part. Tighten pressure screw.