cui.com
date 09/15/2016 │ page 2 of 5CUI Inc │ SERIES: SWI24-E │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current 0.58 A
inrush current
at 100 Vac, full load, 25°C, cold start
at 230 Vac, full load, 25°C, cold start
50
60
A
A
leakage current 0.25 mA
no load power consumption
at 230 Vac
Level VI
CoC Tier 2
0.1
0.075
W
W
OUTPUT
parameter conditions/description min typ max units
regulation ±5 %
hold-up time at full load 10 ms
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection
output shut down
12 Vdc output model
15 Vdc output model
24 Vdc output model
22
32
45
Vdc
Vdc
Vdc
over current protection
outputshutdown,autorecovery
12 Vdc output model
15 Vdc output model
24 Vdc output model
5
4
2.5
A
A
A
short circuit protection outputshutdown,autorecovery
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output at 10 mA for 1 minute 3,000 Vac
isolation resistance input to output at 500 Vdc 10 MΩ
EMI/EMC CE
MTBF asperTelcordiaSR-332,25°C 300,000 hours
RoHS 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 40 °C
storage temperature -20 80 °C
operatinghumidity non-condensing 20 80 %
storagehumidity non-condensing 10 90 %
For more information, please visit the product page | For information on related products, view Dc Power Jacks