SPECIFICATION
80W Constant Voltage + Constant Current LED Driver
HLG-80H series
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.8
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
Adjustable for A/AB-Type only (via built-in potentiometer)
Adjustable for A-Type only (via built-in potentiometer)
16ms at full load 230VAC /115VAC
1200ms,200ms/115VAC 500ms,200ms/230VAC
47 ~ 63Hz
0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
<0.75mA / 277VAC
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
Compliance to
En55015, EN61000-3-2 Class C ( ) ; EN61000-3-3
≧60% ,GB17743 and GB17625.1, EAC TP TC 020@ load
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level ( )surge immunity Line-Earth 4KV, Line-Line 2KV
, EAC TP TC 020
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750(type”HL”), CSA C22.2 No. 250.0-08, UL8750 LISTED for HLG-80H- BL; independent,EN/AS/NZS 61347-1,EN/AS/NZS 61347-2-13
optional models for J61347-1, J61347-2-13, GB19510.1,GB19510.14,EAC TP TC 004,BIS IS15885(for 36A,54A only),IP65 or IP67
357.8K hrs min. MIL-HDBK-217F (25 )℃
195.6*61.5*38.8mm (L*W*H)
0.84Kg; 16pcs/14.4Kg/0.54CUFT
Shut down o/p voltage, re-power on to recover
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
14 ~ 17V
59 ~ 68V
88%
89%
90%
90.5%
91%
91%
91%91% 91%
±2.5%
3 ~ 5A
±2.0%
3 ~ 5A
±1.0%
2.4 ~ 4A
±1.0%
2.04 ~ 3.4A
±1.0%
1.62 ~ 2.7A
±1.0%
1.38 ~ 2.3A
±1.0%
1.02 ~ 1.7A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±2.0%
±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
0.9 ~ 1.5A
±0.5%
±0.5%
±1.0%
1.17 ~ 1.95A
±0.5%
±0.5%
12V
HLG-80H-12 HLG-80H-15 HLG-80H-20 HLG-80H-24 HLG-80H-30 HLG-80H-36 HLG-80H-42 HLG-80H-48 HLG-80H-54
7.2 ~12V
15V
9 ~ 15V
20V
12 ~ 20V
24V
14.4 ~ 24V
30V
18 ~ 30V
36V
21.6 ~ 36V
48V
28.8 ~ 48V
5A 5A 4A 3.4A
2.7A
2.3A
1.7A
60W 75W 80W 81.6W 81W
82.8W
81.6W
150mVp-p 150mVp-p
13.5 ~ 17V
150mVp-p
17 ~ 22V
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
33 ~ 40V
200mVp-p
43 ~ 53V10.8 ~ 13.5V
54V
32.4 ~ 54V
1.5A
81W
200mVp-p
49 ~ 58V
42V
25.2 ~ 42V
1.95A
81.9W
200mVp-p
38 ~ 46V
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
CONSTANT CURRENT REGION
Note.4
EMC IMMUNITY
EMC EMISSION
Note.8
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
18 ~ 24V
23 ~ 30V
28 ~ 35V
35 ~ 43V
41 ~ 49V 54 ~ 63V
48 ~ 58V
COLD START 70A(t =485 s measured at 50% I ) at 230VAC
width peak ; Per NEMA 410
μ
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
90 ~ 305VAC 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
PF 0.96/115VAC, PF 0.96/230VAC, PF 0.94/277VAC @ full load≧≧≧
(Please refer to " " section)POWER FACTOR (PF) CHARACTERISTIC
THD< 20% (@ load 60% / 115VAC,230VAC; @ load 75% / 277VAC)≧≧
(Please refer to TOTAL HARMONIC DISTORTION (THD) section)""
MAX. CASE TEMP.
Tcase= +80℃
Tcase= -40 ~ +80℃
(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. driver
The is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED can only be used behind a switch without permanently
driver
connected to the mains.
9. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 or less.℃
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
11. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
File Name:HLG-80H-SPEC 2018-05-29
approved ; Design refer to UL60950-1, TUV EN60950-1