ACDC
Specification
60 Watts
• Energy Efficiency Level V, ≥15 V
• CEC 2008 & EISA 2007 Compliant
• China Compulsory Certfication (CCC) Qualified
• Single Outputs from 12 V to 30 V
•
Optional Inlet Connectors
• No Load Input Power <0.5 W
• High Power Density
VEH Series
Input
Input Voltage • 90-264 VAC
Input Frequency • 47-63 Hz
Input Current • 1.7 A max
Inrush Current • 50 A max at 230 VAC, cold start at 25 °C
Earth Leakage Current • <1 mA at 240 VAC/50 Hz
Power Factor • EN61000-3-2, class A
No Load Input Power • <0.5 W
Input Protection • Internal T3.15A/250 V fuse in line
Output
Output Voltage • See table
Initial Set Accuracy • ±5% at 50% load
Minimum Load • No minimum load requirement
Hold Up Time • 8 ms min at 115 VAC, full load
Start Up Delay • 3 s max
Start Up Rise Time • 8 ms typical
Transient Response • 4% maxiumum deviation, recovering to
less than 1% within 500 µs for a 50%
step load change
Line Regulation • ±0.5% max
Load Regulation • ±5% max
Ripple & Noise • 200 mv pk-pk max, 20 MHz bandwidth
(see note 1)
Overvoltage Protection • See table
Overload Protection • 110 -180%
Short Circuit Protection • Continuous (hiccup/trip & restart mode
with auto recovery)
Temperature • ±0.04%/˚C
Coefficient
xppower.com
General
Efficiency • See table
Energy Efficiency • Level V ≥15 V
Isolation • 3000 VAC Input to Output,
1500 VAC Input to Ground.
Switching Frequency • 60 kHz ±10 kHz
MTBF • >250 kHrs to Bell Core iss. 6
Environmental
Operating Temperature • 0 ˚C to +60 ˚C derate linearly from 100%
load at +40 ˚C to 50% load at +60 ˚C
Storage Temperature • -20 ˚C to +85 ˚C
Operating Humidity • 5% to 90% RH non-condensing
Storage Humidity • 5% to 95% RH non-condensing
Shock • 6 random drops from 0.7 m with no
damage, 50 g for 20 ms in each of 3 axes
Vibration • 2 g variable frequency from 20 Hz to 30 Hz
EMC & Safety
Emissions • EN55022, level B conducted & radiated
Harmonic Currents • EN61000-3-2 class A
Voltage Flicker • EN61000-3-3
ESD Immunity • EN61000-4-2, level 3 Perf Criteria A
Radiated Immunity • EN61000-4-3, 3 V/m Perf Criteria A
EFT/Burst • EN61000-4-4, level 3 Perf Criteria A
Surge • EN61000-4-5, installation class 3,
Perf Criteria B
Conducted Immunity • EN61000-4-6, level 2 Perf Criteria A
Magnetic Field • EN61000-4-8, 3 A/m Perf Criteria A
Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
Safety Approvals • IEC60950-1, EN60950-1, UL/cUL60950-1,
China Compulsory Certification (CCC)
qualified, Approved as Limited Power
Source