ECONOLINE
DC/DC-Converter
with 3 year Warranty
RW2
Part Number Input Rated Output Output Current Efficiency Max
Voltage Range Voltage Full Load typ./nom Vin Capacitive
DIP16 (Mini & SMD) (VDC) (VDC) (mA) (%) Load
(1)
RW2-053.3S (H2/H3) 4.5 - 9 3.3 500 68 4700µF
RW2-0505S (H2/H3) 4.5 - 9 5 400 73 1000µF
RW2-0512S (H2/H3) 4.5 - 9 12 166 75 1000µF
RW2-0515S (H2/H3) 4.5 - 9 15 134 75 1000µF
RW2-123.3S (H2/H3) 9 - 18 3.3 500 69 4700µF
RW2-1205S (H2/H3) 9 - 18 5 400 75 1000µF
RW2-1212S (H2/H3) 9 - 18 12 166 80 1000µF
RW2-1215S (H2/H3) 9 - 18 15 134 80 1000µF
RW2-243.3S (H2/H3) 18 - 36 3.3 500 70 4700µF
RW2-2405S (H2/H3) 18 - 36 5 400 78 1000µF
RW2-2412S (H2/H3) 18 - 36 12 166 83 1000µF
RW2-2415S (H2/H3) 18 - 36 15 134 83 1000µF
RW2-483.3S (H2/H3) 36 - 72 3.3 500 73 4700µF
RW2-4805S (H2/H3) 36 - 72 5 400 76 1000µF
RW2-4812S (H2/H3) 36 - 72 12 166 81 1000µF
RW2-4815S (H2/H3) 36 - 72 15 134 81 1000µF
RW2-0505D (H2/H3) 4.5 - 9 ±5 ±200 73 ±680µF
RW2-0509D (H2/H3) 4.5 - 9 ±9 ±111 74 ±680µF
RW2-0512D (H2/H3) 4.5 - 9 ±12 ±83 75 ±680µF
RW2-0515D (H2/H3) 4.5 - 9 ±15 ±67 75 ±680µF
RW2-1205D (H2/H3) 9 - 18 ±5 ±200 75 ±680µF
RW2-1209D (H2/H3) 9 - 18 ±9 ±111 78 ±680µF
RW2-1212D (H2/H3) 9 - 18 ±12 ±83 80 ±680µF
RW2-1215D (H2/H3) 9 - 18 ±15 ±67 80 ±680µF
RW2-2405D (H2/H3) 18 - 36 ±5 ±200 78 ±680µF
RW2-2409D (H2/H3) 18 - 36 ±9 ±111 81 ±680µF
RW2-2412D (H2/H3) 18 - 36 ±12 ±83 83 ±680µF
RW2-2415D (H2/H3) 18 - 36 ±15 ±67 83 ±680µF
RW2-4805D (H2/H3) 36 - 72 ±5 ±200 78 ±680µF
RW2-4809D (H2/H3) 36 - 72 ±9 ±111 81 ±680µF
RW2-4812D (H2/H3) 36 - 72 ±12 ±83 83 ±680µF
RW2-4815D (H2/H3) 36 - 72 ±15 ±67 83 ±680µF
Standard Isolation is 1kVDC. Add suffix “/H2” for 2kVDC Isolation, “/H3” for 3kVDC Isolation.
Add no suffix for standard case style, “/SMD” for SMD package or “/B” for smaller case size
e.g. RW2-0505S/H3, RW2-0505D/H2/SMD or RW2-0505S/B
Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in
under 1second without damage to the converter
Note 2: The RW2 series requires a minimum of 10% load on the output to maintain specified
regulation. Operating under no-load conditions will not damage these devices; however,
they may not meet all listed specifications.
2 Watt
DIP16, Mini
DIP16
& SMD
Single
& Dual
Output
●
2:1 Wide Range Voltage Input
●
1kVDC, 2kVDC and 3kVDC Isolation
●
Approved for Medical Applications
●
Continuous Short Circuit Protection
●
Low Ripple and Noise
●
DIP16, mini DIP16 and SMD Cases Styles
●
Efficiency to 83%
Features
Regulated
Converters
Selection Guide