Ultra-Sensitive Dual-Channel Quadrature
Hall-Effect Bipolar Switch
A3425
5
Allegro MicroSystems, Inc.
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com
MAGNETIC CHARACTERISTICS, K Package
5
Operate Point: B > B
OP
B
OP(A)
, B
OP(B)
– 7 35 G
Release Point: B < B
RP
B
RP(A)
, B
RP(B)
–35 –7 – G
Hysteresis: B
OP(A)
– B
RP(A)
,
B
OP(B)
– B
RP(B)
B
HYS(A)
, B
HYS(B)
51640 G
Symmetry: Channel A, Channel B,
B
OP(A)
+ B
RP(A)
,
B
OP(B)
+ B
RP(B)
SYM
A
, SYM
B
–40 – 40 G
Operate Symmetry: B
OP(A)
– B
OP(B)
SYM
AB(OP)
–30 – 30 G
Release Symmetry: B
RP(A)
– B
RP(B)
SYM
AB(RP)
–30 – 30 G
MAGNETIC CHARACTERISTICS, L Package
5
Operate Point: B > B
OP
B
OP(A)
, B
OP(B)
– 7 30 G
Release Point: B < B
RP
B
RP(A)
, B
RP(B)
–30 –7 – G
Hysteresis: B
OP(A)
– B
RP(A)
,
B
OP(B)
– B
RP(B)
B
HYS(A)
, B
HYS(B)
51435 G
Symmetry: Channel A, Channel B,
B
OP(A)
+ B
RP(A)
,
B
OP(B)
+ B
RP(B)
SYM
A
, SYM
B
–35 – 35 G
Operate Symmetry: B
OP(A)
– B
OP(B)
SYM
AB(OP)
–25 – 25 G
Release Symmetry: B
RP(A)
– B
RP(B)
SYM
AB(RP)
–25 – 25 G
1
When operating at maximum voltage, never exceed maximum junction temperature, T
J(max)
. Refer to power derating curve charts.
2
Device will survive the current level specifi ed, but operation within magnetic specifi cation cannot be guaranteed.
3
Short circuit of the output to VCC is protected for the time duration specifi ed.
4
Maximum specifi cation limit is equivalent to I
CC(max)
+ 3 mA.
5
Magnetic fl ux density, B, is indicated as a negative value for north-polarity magnetic fi elds, and as a positive value for south-polarity
magnetic fi elds. This so-called algebraic convention supports arithmetic comparison of north and south polarity values, where the
relative strength of the fi eld is indicated by the absolute value of B, and the sign indicates the polarity of the fi eld (for example, a
–100 G fi eld and a 100 G fi eld have equivalent strength, but opposite polarity).
OPERATING CHARACTERISTICS (continued) Valid over operating temperature ranges unless otherwise noted; typical
data applies to V
CC
= 12 V, and T
A
= 25ºC
Characteristic Symbol Test Conditions Min. Typ. Max Units
EMC
Contact Allegro MicroSystems for EMC performance.