PXD2024S05

Installation Data Sheet
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
PXD Series (single output) DC-DC Converters
The PXD is a DC-DC converter which provides a fully isolated and regulated output at power levels up to 20 watts. It accepts a wide
range DC input. The converter may be operated with or without the input and output pins grounded.
Table of Contents
General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Fusing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Installation Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Soldering and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
EMI Filter (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Minimum Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Outline Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Remote On-Off Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Thermal Consideration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
External Trim (output voltage adjustment) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Trim Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
General Safety Instructions
These products are designed to be PCB mounted and for use
within other equipment or enclosures. For safe installation and
operation, carefully follow the instructions below:
1. Do not install, test, or operate the products near water or
spill liquid on them.
2. Do not operate these products unless they are securely
fastened.
3. These products must be installed in a restricted access
location accessible to authorized personnel only.
4. These products must be professionally installed in
accordance with the prevailing electrical wiring regulations
and safety standards.
5. The output power taken from the unit must not exceed the
ratings stated in the catalog datasheet.
6. Ensure adequate ventilation is provided to allow air to
circulate.
7. This product has functional insulation between input and
output and therefore the DC source to this product must
be reinforced or double insulated to the AC input in
accordance with IEC/EN 60950-1 to achieve SELV output.
Fusing
An external ceramic sand-filled fuse is needed for protection.
12V input ~ 250V, F8A, HBC
24V input ~ 250V, F5A, HBC
48V input ~ 250V, F5A, HBC
Installation Method
The unit can be mounted in any direction. Position single or
multiple units with proper spacing to allow for adequate air
ventilation. The case temperature of each unit should not exceed
the temperature range as noted in the data sheet.
Avoid placing PCB traces for the DC input and DC output directly
under the unit to limit the possibility of unwanted conducted noise.
Soldering and Cleaning
Flow soldering : 260±10°C less than 15 seconds
Soldering iron : 370±10°C less than 5 seconds
Note: The pins of this module are coated with Tin. To assure the
solder-ability, modules should be kept in their original shipping
containers to provide adequate protection. Also, the storage
environment should be controlled to prevent oxidation of the pins.
Following wave solder, the converters should be given an
opportunity to cool to within 10°C of the cleaning solution
temperature. Cleaning while at a higher temperature may
increase the risk of vacuum absorption of the solution into the
converter between the pins and potting material during cooling.
It is recommended that during the wash process, the date code
screening is protected to avoid erasure.
Installation Data Sheet
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
Block Diagram
EMI Filter (Optional)
Input filter components (C1, C2, L1) are used to help meet special
conducted emissions requirements for the PXD product. These
components should be mounted as close as possible to the DC-
DC converter; and all leads should be minimized to decrease
radiated noise.
C1 L1 C2
PXD10 22µF 100v 3.3µH 22µF, 100V
Electrolytic Electrolytic
PXD15, PXD20 1µF, MLC 5.5µH 39µF 100V
Electrolytic
Minimum Load
The PXD20 does not require a minimum load for proper
operation.
A 10% (of full load) minimum load is required on PXD10 and
PXD15 models to meet the performance specifications. These
models do not maintain regulation and operate properly under a
no-load condition.
Pin Assignments
Outline Drawing
Appropriate hook-up location for
test equipment to monitor output.
0.1uf
DC + Fuse +Vin PXD +Vo
1uf
- -Vin -Vo
Remote On / Off
System Ground Trim
Source
Load
O
p
tional
EMI
Filter
DVM
Coax cable Oscillosco
p
e
50
L1
C1 C2
10
&
15
Watt 20
Watt
Pin Connection Pin Connection
1 + Input 1 + Input
2 - Input 2 - Input
3 + Output 3 + Output
4 No Pin 4 Trim
5 - Output 5 - Output
6 Remote On / Off 6 Remote On / Off
1. All dimensions in Inches (mm)
2. Pin Pitch tolerance ±0.014
(
0.35
)
0.40
(10.2)
0.40
(10.2)
0.50
(12.7)
1.00(25.4)
0.10(2.5)
0.20(5.1)
0.22(5.6)
0.40
(10.2)
12
34 5
6
Bottom
View
Installation Data Sheet
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout= 1.485 1.470 1.455 1.440 1.425 1.410 1.395 1.380 1.365 1.350 Volts
RD= 5.704 2.571 1.527 1.005 0.692 0.483 0.334 0.222 0.135 0.065 KOhms
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout= 1.515 1.530 1.545 1.560 1.575 1.590 1.605 1.620 1.635 1.650 Volts
RU= 4.578 2.065 1.227 0.808 0.557 0.389 0.270 0.180 0.110 0.054 KOhms
PXD20 1.5V
Trim Tables
Remote On-Off Control
Negative L
ogic
To turn the module on and off, the user must supply a switch (or
equivalent circuit below) to control the voltage between the on/off
terminal Von/off and the Vi(-) input terminal. With an open circuit,
the module is normally off. To turn the module on, the voltage on
the Von/off pin needs to be 0V-1.2V. The maximum current Ion/off
should be limited to less than 200µA.
P
ositive Logic
To turn the module on and off, the user must supply a switch (or
equivalent circuit below) to control the voltage between the on/off
terminal Von/off and the Vi(-) input terminal. With an open circuit
the module is normally on. To turn the module off, the voltage on
the Von/off pin needs to be 0V-1.2V. The maximum current Ion/off
should be limited to less than 100µA.
Below are five possible circuits for driving the ON/OFF Pin:
Thermal Consideration
The power module operates in a variety of thermal environments;
however, sufficient cooling should be provided to help ensure
reliable operation of the unit. Heat is removed by conduction,
convention, and radiation to the surrounding environment. Proper
cooling can be verified by
measuring the case
temperature. The case
temperature (Tc) should be
measured at the position
indicated in figure to the right.
When operating the module,
adequate cooling must be
provided to maintain the case
temperature at or below 100°C.
Maintaining a lower temperature
will yield higher reliability of the device. Optimum cooling is
obtained with forced convection.
External Trim (output voltage
adjustment, PXD20 - 20Watt only)
Output voltage set point adjustment allows the user to increase or
decrease the output voltage set point of a module. This is
accomplished by connecting an external resistor between the TRIM
pin and either the (+)Vout or (-)Vout pins. With an external resistor
between the TRIM and (+)Vout pin, the output voltage set point
decreases. With an external resistor between the TRIM and (-)Vout
pin, the output voltage set point increases.
See the following pages for values.
 (+) Vout (+) Vin
 (-) Vout
(-) Vin
TRIM (20W)
CTRL
Top View
On/Off Control
Positive Logic
(Permanently Disabled)
Positive Logic
(Permanently Enabled)
On/Off Control
Open Collector Remote On/Off
On/Off Control
On/Off Control
Opto Isolated Remote On/Off
On/Off Control
TTL/
CMOS
Flow Rate
ΘΘ
Convection* 16.20°C/W
100LFM 12.98
200LFM 10.47
300LFM 8.47
400LFM 6.61
500LFM 6.12
Heatsink** 10.00
* Mounted vertically
** Optional heatsink 7G0020A (includes adhesive pad)

PXD2024S05

Mfr. #:
Manufacturer:
TDK-Lambda
Description:
Isolated DC/DC Converters 20W 5V 4A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: