6612_OMU_S2+2_URT_V1_14 Firmware Description Document UG_6612_017
28 Rev. 1.0
Table 4 lists the narrowband measurement outputs for Outlet 2.
Table 4: Outlet 2 MPU Outputs for Narrowband Method
Output
Location
(hex)
LSB Comment Example
Delta
Temperature
40 0.1 °C
Temperature difference from 22° C.
Note: Duplicate of address 0x00
(see Table 2).
If external temperature is 32 °C
)40?<CR>
Returns:
+10.0
Line
Frequency
41 0.01 Hz
Line Frequency
Note: Duplicate of address 0x01
(see Table 2).
If the line frequency is 60 Hz:
)41?<CR>
Returns:
+60.00
Alarm Status 42
Bit 0 Minimum Temperature
Alarm.
Definition for Status Register
Bit 1 Maximum Temperature
Alarm.
Bit 2 Minimum Frequency Alarm.
Bit 3 Maximum Frequency Alarm.
Bit 4 SAG Voltage Alarm.
Bit 5 MINVA under minimum
voltage on VA input.
Bit 6 MAXVA over maximum
voltage on VA input.
Bit 7 MAXIA_NB maximum
narrowband current exceeded on
Outlet 1.
Bit 8 MAXIA_WB maximum
wideband current exceeded on
Outlet 1.
Bit 9 PFA_NB negative
Narrowband Power Factor
Negative Threshold Alarm for
Outlet 1. Only available is )F2 bit 2
is 1.
Bit 10 PFA_NB positive
Narrowband Power Factor Positive
Threshold Alarm for Outlet 1.
Bit 11 PFA_WB negative
Wideband Power Factor Negative
Threshold Alarm for Outlet 1. Only
available is )F2 bit 2 is 1.
Bit 12 PFA_WB positive
Wideband Power Factor Positive
Threshold Alarm for Outlet 1.
Bit 13 MAXIB_NB maximum
narrowband current exceeded on
Outlet 2.
Bit 14 MAXIB_WB maximum
wideband current exceeded on
Outlet 2.
Bit 15 PFB_NB negative
Narrowband Power Factor
Negative Threshold Alarm for
Outlet 2. Only available is )F2 bit 2
is 1.
Alarms become “1” when
thresholds exceeded.
Note: Additional Status Alert is
Located at addr 0xBD (see Table
8).
Note: When AC voltage input is
less than or equal to 10 V
RMS
,
Only MINVA alarm is active.
All measurements are
forced to 0 except power
factor, which is forced to 1.
Note: The frequency measurement
is forced to 0 as long as the SAG
voltage alarm is active.
UG_6612_ 017 6612_OMU_S2+2_URT_V1_14 Firmware Description Document
Rev. 1.0 29
Output
Location
(hex)
LSB Comment Example
Bit 16 PFB_NB positive
Narrowband Power Factor Positive
Threshold Alarm for Outlet 2.
Bit 17 PFB_WB negative
Wideband Power Factor Negative
Threshold Alarm for Outlet 2. Only
available is )F2 bit 2 is 1.
Bit 18PFB_WB positive
Wideband Power Factor Positive
Threshold Alarm for Outlet 2.
Bit 19 MAXIT_WB maximum
total wideband current exceeded on
both Outlet 1 and Outlet 2.
Bit 20 MAXIT_NB maximum
total narrowband current exceeded
on both Outlet 1 and Outlet 2.
Bit 21 CREEP A Alert Creep
Alert on Outlet 1.
Bit 22 CREEP B Alert Creep
Alert on Outlet 2.
Bit 23 Line/Neutral Reversal
detected. Only available in non-
isolated mode (CESTATE, Bit 2=1)
Bit 24 Reserved.
Bit 25 Reserved.
Bit 26 Unexpected Reset.
Bits 27-31 Reserved.
Note: Duplicate of address 0x02
(see Table 2).
Irms_nb B
Overcurrent
Event Count
43
Counter increments on each edge
event.
If four narrowband over current
events have occurred on Outlet 2:
)43?<CR>
Returns: +4
Vrms Under
Voltage
Event Count
44
Counter increments on each edge
event.
Note: Duplicate of address 0x04
(see Table 2).
If four under voltage events have
occurred:
)44?<CR>
Returns: +4
Vrms Over
Voltage
Event Count
45
Counter increments on each edge
event.
Note: Duplicate of address 0x06
(see Table 2).
If 4 over voltage events have
occurred:
)45?<CR>
Returns: +4
Vrms A 46 mV
Vrms voltage
Note: Duplicate of address 0x06
(see Table 2).
If the line voltage is 120 V
)46?<CR>
Returns:
+120.000
Watts B 47 mW
Outlet 2 active power measurement
(per second).
If 120 Watts are measured on
Outlet 2
)47?<CR>
Returns:
+120.000
Wh B 48 mWh
Outlet 2 active accumulated energy
measurement (per hour).
If 120 Wh are measured on
Outlet 2
)48?<CR>
Returns:
+120.000
6612_OMU_S2+2_URT_V1_14 Firmware Description Document UG_6612_017
30 Rev. 1.0
Output
Location
(hex)
LSB Comment Example
Total Cost B 49 mUnits Outlet 2 cost of Wh B.
If the total cost is 102.536 units on
Outlet 2
)49?<CR>
+102.536
Irms_nb B 4A mArms
Outlet 2 narrowband rms current
measurement.
If narrowband current measured on
Outlet 2 is 12 Amps
)4A?<CR>
Returns:
+12.000
VARs_nb B 4B mW
Outlet 2 narrowband reactive power
measurement (per second).
If narrowband 120 VARs are
measured on Outlet 2
)4B?<CR>
Returns:
+120.000
VAs_nb B 4C mW
Outlet 2 narrowband apparent
power measurement (per second).
If narrowband 120 VAs are
measured on Outlet 2
)4C?<CR>
Returns:
+120.000
Power
Factor_nb B
4D
Outlet 2 narrowband power factor.
The output will be between -0.950
and 1.000. Positive power factor is
defined as current lagging voltage
(inductive). Negative power factor
is defined as voltage lagging
current (capacitive).
If the narrowband power factor on
Outlet 2 is 0.95
)4D?<CR>
Returns:
+0.950
Phase
Angle_nb B
4E
Outlet 2 narrowband phase angle.
The output will be between 180.000
and
-180.000.
If the narrowband phase angle
measured on Outlet 2 is 60
degrees
)4E?<CR>
Returns:
+60.000
Reserved 4F Reserved
Reserved
Vrms A Min 50 mV
Minimum Vrms measured
Note: Duplicate of address 0x10
(see Table 2).
If the minimum line voltage
measured was 105 V
)50<CR>
Returns:
+15.000
Vrms A Max 51 mV
Maximum Vrms measured
Note: Duplicate of address 0x11
(see Table 2).
If the maximum line voltage
measured was 130 V
)51<CR>
Returns:
+130.000
Watts B Min 52 mW
Minimum Outlet 2 active power
measured (per second).
If the minimum power measured on
Outlet 2 is 80 Watts
)52?<CR>
Returns:
+80.000
Watts B Max 53 mW
Maximum Outlet 2 active power
measured (per second).
If the maximum power measured
on Outlet 2 is 200 Watts
)53?<CR>
Returns:
+200.000

78M6612-DB/OMU-USB