2800961

https://www.phoenixcontact.com/pi/products/2800961
04/30/2017Page1/4
Type 3 surge protection device-PT 2-PE/S-60AC/FM-2800961
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Pluggable type 3 arrester (device protection) for single-phase power supply networks with separate N and PE
(3-conductor system: L1, N, PE) with remote indication contact.
The figure shows the PT 2-PE/
S-230AC/FM version
Key Commercial Data
Packing unit 10 STK
GTIN
GTIN 4046356660266
Technical data
Dimensions
Height 90 mm
Width 17.7 mm
Depth 65.5 mm
Horizontal pitch 1 Div.
Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -40 °C ... 85 °C
General
Housing material PA
Flammability rating according to UL 94 V0
Color black
Standards for cearances and creepage distances IEC60664-1
Design DIN rail module, two-section, divisible
Mounting type DIN rail: 35 mm
https://www.phoenixcontact.com/pi/products/2800961
04/30/2017Page2/4
Type 3 surge protection device-PT 2-PE/S-60AC/FM-2800961
Technical data
General
Number of positions 2
Direction of action 1L-N & N-PE
Protective circuit
IEC test classification III
T3
EN type T3
Nominal voltage U
N
60 V AC
Arrester rated voltage U
C
100 V AC
95 V DC
Nominal frequency f
N
50 Hz
60 Hz
Residual current I
PE
≤ 1.5 µA
Nominal discharge current I
n
(8/20) µs
2.5 kA
Nominal discharge current I
n
(8/20) µs (L-N)
2.5 kA
Max. discharge current I
max
(8/20) µs
6.5 kA
Combination wave U
OC
4 kV
Voltage protection level U
p
(L-N)
≤ 400 V
Residual voltage at In, (L-N) ≤ 420 V
Response time t
A
(L-N)
≤ 25 ns
Response time t
A
(L-PE)
≤ 100 ns
Response time t
A
(N-PE)
≤ 100 ns
Max. required back-up fuse 25 A (gL)
25 A (MCB B/C)
Short-circuit resistance I
P
with max. backup fuse (effective)
1.5 kA
Surge protection fault message Optical, remote indicator contact
Non-heating apparatus connection, power supply
Connection method Screw connection
Connection method IN Screw terminal blocks
Connection method OUT Screw terminal blocks
Screw thread M3
Tightening torque 0.5 Nm
Stripping length 8 mm
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Remote indication contact
https://www.phoenixcontact.com/pi/products/2800961
04/30/2017Page3/4
Type 3 surge protection device-PT 2-PE/S-60AC/FM-2800961
Technical data
Remote indication contact
Connection name Remote fault indicator contact
Switching function N/C contact
Connection method Screw connection
Screw thread M3
Tightening torque 0.8 Nm
Stripping length 8 mm
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Maximum operating voltage U
max.
AC
250 V
Max. operating current I
max
3 A AC
Standards and Regulations
Standards/specifications IEC 61643-1 2005
EN 61643-11/A11 2007
UL 1449 ed. 2
Drawings
Circuit diagram
IN
OUT
5
6
3
4
1
2
11
12
N
L
PE
PE
N
L
Dimensional drawing
44,8
90
51,5
65,5

2800961

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Surge Suppressors PT 2-PE/S-60AC/FM
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet