Evaluates: MAX3669
MAX3669 Evaluation Kit
_______________________________________________________________________________________ 7
Electrical Output. Remove for optical operation.Electrical Output SMAJ5
TTL low level indicates a failure in the APC loop.Fail Indicator Test PointTP1
Automatic Power Control Adjustment. For closed-loop operation, R16
adjusts the monitor-diode current level.
R
APCSET
R16
Laser-Bias Current Adjustment. In open-loop mode, R15 adjusts the laser-
bias current. In closed-loop operation, R15 adjusts the maximum laser-bias
current.
R
BIASMAX
R15
Laser Modulation Current AdjustmentR
MODSET
R14
Enable/Disable the Output Currents. Shunting disables the part. Remove
shunt for normal operation.
OUTPUT DISABLEP1
Refer to the Design section of the MAX3669 data sheet. Set APC current;
then increase bias current until LED goes off (LED is illuminated when the
APC loop is open and off when the APC loop is closed).
APC Fail Indicator LEDD1
COMPONENT FUNCTIONNAME
Adjustment and Control Descriptions
Figure 4b. MAX3669 EV Kit Component Placement Guide—
Component Side