https://www.phoenixcontact.com/pi/products/1701144
08/18/2018Page4/6
PCB terminal block-MKDS 3/ 6-5,08-1701144
Technical data
Air clearances and creepage distances
Minimum clearance - inhomogeneous field (III/2) 3 mm
Minimum clearance - inhomogeneous field (II/2) 3 mm
Minimum creepage distance value (III/3) 3.2 mm
Minimum creepage distance value (III/2) 2 mm
Minimum creepage distance value (II/2) 3.2 mm
Note on connection cross section With connected conductor 4 mm² (solid).
Current carrying capacity / derating curves
Specification IEC 60998-2-1 (in parts)
Vibration test
Resistance to ageing, to humidity conditions, to ingress of solid objects
and to harmful ingress of water
Test passed IEC 60998-1:2002-12 168 h/100°C 48 h/30 °C/92 %
Test result Test passed
Test specification IEC 60998-1:2002-12
Dry heat 168 h/100°C
Humid heat 48 h/30 °C/92 %
Resistance to ageing, humidity and penetration of solids
Test result Test passed
Test specification IEC 60998-1:2002-12
Dry heat 168 h/100°C
Humid heat 48 h/30 °C/92 %
Standards and Regulations
Connection in acc. with standard EN-VDE
Flammability rating according to UL 94 V0
Environmental Product Compliance
REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings