4
LT1389
PARAMETER CONDITIONS MIN TYP MAX UNITS
Reverse Breakdown Voltage LT1389BCS8 (I
R
= 1.5µA) 4.99625 5.000 5.00375 V
–0.075 0.075 %
LT1389BCS8 (I
R
= 1.5µA) ● 4.979 5.000 5.021 V
–0.42 0.42 %
Reverse Breakdown Change 1.5µA ≤ I
R
≤ 200µA 0.2 1.5 mV
with Current (Note 4)
● 0.2 3 mV
200µA ≤ I
R
≤ 2mA 0.3 4 mV
● 0.3 6 mV
Minimum Operating Current ● 1 µA
Temperature Coefficient I
R
= 1.5µA ● 12 50 ppm/°C
Reverse Dynamic Impedance (Note 5) 1.5µA ≤ I
R
≤ 2mA 0.75 2 Ω
● 0.75 3 Ω
Low Frequency Noise (Note 6) I
R
= 1.5µA, 0.1Hz ≤ f ≤ 10Hz 100 µV
P-P
5V ELECTRICAL CHARACTERISTICS
The ● denotes specifications which apply over the full operating
temperature range, otherwise specifications are at T
A
= 25°C. (Note 3)
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: If the part is stored outside of the specific operating temperature
range, the output may shift due to hysteresis.
Note 3: ESD (Electrostatic Discharge) sensitive device. Use proper ESD
handling precautions.
Note 4: Output requires 0.1µF for operating current greater than 1mA.
Note 5: This parameter is guaranteed by “reverse breakdown change with
current” test.
Note 6: Peak-to-peak noise is measured with a single highpass filter at
0.1Hz and 2-pole lowpass filter at 10Hz.