VN800PS-E Electrical specifications
Doc ID 15610 Rev 4 9/27
I
INH
High level input current V
IN
=3.25 V - 10 µA
V
I(hyst)
Input hysteresis voltage 0.5 - V
I
IN
Input current V
IN
=V
CC
=36V - 200 µA
Table 7. Input pin (continued)
Symbol Parameter Test conditions Min. Typ. Max. Unit
Table 8. V
CC
- output diode
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
F
Forward on voltage -I
OUT
= 0.6 A; T
j
= 150 °C - - 0.6 V
Table 9. Status pin
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
STAT
Status low output voltage I
STAT
=1.6 mA - - 0.5 V
I
LSTAT
Status leakage current Normal operation; V
STAT
=V
CC
=36V - - 10 µA
C
STAT
Status pin input
capacitance
Normal operation; V
STAT
=5V - - 30 pF
Table 10.
Protections
(1)
Symbol Parameter Test conditions Min. Typ. Max. Unit
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature 135 °C
T
hyst
Thermal hysteresis 7 15 °C
T
SDL
Status delay in overload
condition
T
j
>T
jsh
20 µs
I
lim
DC short circuit current V
CC
=24V; R
LOAD
=10mΩ 0.7 2 A
V
demag
Turn-off output clamp voltage I
OUT
=0.5A; L=6mH V
CC
-47 V
CC
-52 V
CC
-57 V
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related diagnostic signals
must be used together with a proper software strategy. If the device is subjected to abnormal conditions, this software must