Timing function ON/OFF and cycle operations up to one week
Contact type Two SPST-NO time limit contacts with manual override switches
Terminal form Screw terminals
Mounting Panel mounting Surface or track mounting
Part number H5S-B H5S-FB
Supply voltage 100 to 240 VAC, 50/60 Hz
Description Part number
Hard plastic cover Y92A-72C
Track mounting adapter for H5S-FB Y92F-90
Mounting track 50 cm (1.64 ft) length PFP-50N
1 m (3.28 ft) length PFP-100N
End plate PFP-M
Time setting range 00:00 a.m. to 11:59 p.m.
Program capacity 24 steps: ON = 1 step, OFF = 1 step, CYCLE = 4 steps, PULSE = 1 step
Cycle length From 1 minute up to a full week
Display time division 1 minute
Operation Weekly operation (multiple-day operation possible)
Cycle operation
Pulse-out operation (pulse width can be set in units of 1 second from 1 to 59 seconds and in units
of 1 minute from 1 to 60 minutes)
Day override operation (operation for one day can be also executed on any other day)
Forced ON/OFF operation
Manual or automatic operation selectable on recovery from power failure
Timer Provides Prompted Programming,
Flexibility in Programs Within the Week
AM/PM display
24 program steps
A different program possible each day
Over midnight settings possible
Two independent 15 A control circuits
with manual override
Automatic or manual operation following
power failure
Field-adjustable ON/OFF, cycle and
pulse output
Easy-to-use prompted programming
Wide supply voltage range
Battery backup for memory protection
Protective cover and other accessories
may be ordered separately
TIMERS
TIME RANGES
ACCESSORIES
Ordering Information
1
Weekly Timer H5S
H5S H5S
2
Part number H5S-B H5S-FB
AC 100 to 240 V, 50/60 Hz
DC
Operating voltage 85 to 110% of rated voltage (85 to 264 VAC), 50/60 Hz
AC 10 VA
DC
Timing functions ON and OFF programming
Reset (boot) input No-voltage, 0.2 sec minimum
Type Time limit SPST-NO x 2 circuits
Pulse 1 sec to 59 seconds or 1 min to 60 min
Max. load 15 A, 250 VAC resistive load
Min. load 100 mA, 5 VDC
Repeat accuracy ±0.01%, ±0.05 second max.
Long-term error ±15 seconds per month at 25°C (77°F); ±4 seconds/week, ±1 minute/4 months
Setting error Included in "Repeat Accuracy"
Indicators 10 mm LCD; day, hours (a.m., p.m.), minutes (0:00 to 11:59 a.m., 0:00 to 11:59 p.m.)
Digital display of program steps during operation
Timing chart display of program steps during operation
Materials Plastic
Mounting Panel Surface and track with adapter
Connections Terminal screws
Weight 200 g (7 oz.)
Approvals UL/CSA/SEV
Operating ambient temperature -10° to 55°C (14° to 131°F)
Humidity 35 to 85% RH
Vibration Mechanical durability 10 to 55 Hz, 0.75 mm (0.03 in) double amplitude
Malfunction durability 10 to 55 Hz, 0.5 mm (0.02 in) double amplitude
Shock Mechanical durability 30 G
Malfunction durability 10 G
Variation due to voltage change Included in "Repeat accuracy"
Variation due to temperature change Included in "Repeat accuracy"
Insulation resistance 100 M minimum between current-carrying terminals and non-current-carrying metal parts;
operation circuit and contact control output circuit; non-continuous contacts
Dielectric strength 2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminals and non-current-
carrying metal parts, and operation circuit and contact control output circuit.
1,000 VAC, 50/60 Hz for 1 minute between non-continuous contacts
Service life Electrical 50,000 operations minimum, 15 A, 250 VAC, resistive load
50,000 operations minimum, 1 HP, 250 VAC, motor load
50,000 operations minimum, 10 A, 250 VAC, inductive load (p.f.=0.7)
50,000 operations minimum, 100 W, 100 VAC, lamp load
10,000 operations minimum, 300 W, 100 VAC, lamp load
Supply
voltage
Power
consumption
Control
output
Specifications
H5S H5S
3
49
(1.93)
Dimensions
Unit: mm (inch)
TIMERS
H5S-B Panel-Mounting Type
72
(2.83)
72
(2.83)
67.6
(2.66)
58.5
(2.30)
67.6
(2.66)
67.6
(2.66)
72
(2.83)
72
(2.83)
126.7
(4.99)
96
(3.78)
58.5
(2.30)
68
(2.68)
The hard plastic protective cover prevents
accidental resetting. It also shields the front
panel from dirt and water. The cover is
intended for use in areas where unusual
service conditions do not exist.
75
(2.95)
12.5 (0.49)
overall
depth
H5S-FB Surface-Mounting Type
75
(2.95)
Track mounting adapter
Y92F-90 (order separately)
PROTECTIVE COVER
Y92A-72C
49
(1.93)
72
72
(2.83)
37
(1.46)
17.7 (0.69)

H5S-B

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
Timers PANEL MT WEEKLY
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet