cui.com
CUI Inc │ SERIES: VAWQ12 │ DESCRIPTION: DC-DC CONVERTER date 09/19/2013 │ page 2 of 5
INPUT
parameter conditions/description min typ max units
operating input voltage
9.0
18.0
24
48
36.0
75.0
Vdc
Vdc
CTRL
1
module on
3 40 Vdc
or open circuit
module off 0 1.2 Vdc
Note: 1. Control pin voltage referenced to GND
OUTPUT
parameter conditions/description min typ max units
output power 1.2 12 W
line regulation input voltage from low to high ±0.2 ±0.5 %
load regulation measured from 10% load to full load ±0.5 ±1.5 %
voltage accuracy ±1 ±3 %
switching frequency measured from 10% load to full load 350 400 450 kHz
temperature coeffi cient ±0.02 %/°C
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection
3.3 V model
5 V model
12 V model
15 V model
4.3
6
13
16
Vdc
Vdc
Vdc
Vdc
under voltage protection
24 V input
module on 8.8 9 Vdc
module off 8.3 8.5 Vdc
48 V input
module on 17 17.5 Vdc
module off 16.5 17 Vdc
short circuit protection continuous, automatic recovery
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage for 1 minute at 1 mA max. 1,500 Vdc
isolation resistance at 500 Vdc 1,000 MΩ
MTBF MIL-HDBK-217F, at 25°C 1,000,000 hours
RoHS compliant yes
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature see derating curves -40 85 °C
storage temperature -55 125 °C
case temperature 95 105 °C
storage humidity non-condensing 95 %
lead temperature 1.5 mm from case for 10 seconds 300 °C