RI-46A

Catch Us on the Web! www.cotorelay.com E-Mail us: sales@cotorelay.com
68
RI-46 Series
RI-46 SRI-46 S
RI-46 SRI-46 S
RI-46 S
ERIESERIES
ERIESERIES
ERIES
Micro dry-reed switch hermetically sealed in a gas-filled glass envelope.
Single-pole, single-throw (SPST) type, having normally open contacts,
and containing two magnetically actuated reeds.
The switch is of the double-ended type and may be actuated by an
electromagnet, a permanent magnet or a combination of both.
The device is intended for use in relays, sensors, pulse counters or
similar devices.
RI-46 SRI-46 S
RI-46 SRI-46 S
RI-46 S
ERIESERIES
ERIESERIES
ERIES
F F
F F
F
EAEA
EAEA
EA
TURESTURES
TURESTURES
TURES
u Can switch main voltage
u Can handle up to 40 W load
u Contact layers: Gold, sputtered ruthenium
u Superior glass-to-metal seal and blade alignment
u Excellent life expectancy and reliability
GG
GG
G
ENERALENERAL
ENERALENERAL
ENERAL
DATADATA
DATADATA
DATA
FORFOR
FORFOR
FOR
ALLALL
ALLALL
ALL
MODELSMODELS
MODELSMODELS
MODELS
RI-46 RI-46
RI-46 RI-46
RI-46
AT-Customization / Preformed Leads
Besides the standard models, customized products can also
be supplied offering the following options:
! Operate and release ranges to customer specification
! Cropped and/or preformed leads
CC
CC
C
OILSOILS
OILSOILS
OILS
All characteristics are measured using the Philips Standard
Coil. For definitions of the Philips Standard Coil and the
standard MIL Coil, refer to “Application Notes” in the
Reed Switch Technical & Application Information Section
of this catalog.
RelaRela
RelaRela
Rela
tionship betwtionship betw
tionship betwtionship betw
tionship betw
een Philips Standareen Philips Standar
een Philips Standareen Philips Standar
een Philips Standar
d Coil and d Coil and
d Coil and d Coil and
d Coil and
Stan-Stan-
Stan-Stan-
Stan-
dardar
dardar
dar
d MIL Coild MIL Coil
d MIL Coild MIL Coil
d MIL Coil
Operate value of standard MIL Coil = 0.79 x operate value
of Philips Standard Coil + 2.26 AT.
Release value of standard Mil Coil = 0.83 x release value of
Philips Standard Coil + 1.31 AT.
LL
LL
L
IFEIFE
IFEIFE
IFE
EXPECTEXPECT
EXPECTEXPECT
EXPECT
ANCYANCY
ANCYANCY
ANCY
ANDAND
ANDAND
AND
RELIABILITYRELIABILITY
RELIABILITYRELIABILITY
RELIABILITY
The life expectancy data given below are valid for a coil
energized at 1.5 times the published maximum operate
value for each type in the RI-46 series.
No-load conditions (operNo-load conditions (oper
No-load conditions (operNo-load conditions (oper
No-load conditions (oper
aa
aa
a
ting frting fr
ting frting fr
ting fr
equencequenc
equencequenc
equenc
y:y:
y:y:
y:
100 Hz) 100 Hz)
100 Hz) 100 Hz)
100 Hz)
Life expectancy: min. 10
8
operations with a failure rate of
less than 10
-9
with a confidence level of 90%.
End of life criteria:
Contact resistance > 1 W after 2 ms
Release time > 2 ms (latching or contact sticking).
Loaded conditions (rLoaded conditions (r
Loaded conditions (rLoaded conditions (r
Loaded conditions (r
esistiesisti
esistiesisti
esisti
vv
vv
v
e load:e load:
e load:e load:
e load:
20 20
20 20
20
VV
VV
V
; 500 mA;; 500 mA;
; 500 mA;; 500 mA;
; 500 mA;
operoper
operoper
oper
aa
aa
a
ting frting fr
ting frting fr
ting fr
equencequenc
equencequenc
equenc
y:y:
y:y:
y:
125 Hz) 125 Hz)
125 Hz) 125 Hz)
125 Hz)
RI-46AARI-46AA
RI-46AARI-46AA
RI-46AA
Life expectancy: min. 10
7
operations with a failure rate of
less than 10
-8
with a confidence level of 90%.
End of life criteria:
Contact resistance > 2 W after 2.5 ms
Release time > 2.5 ms (latching or contact sticking).
RI-46A; RI-46B; RI-46CRI-46A; RI-46B; RI-46C
RI-46A; RI-46B; RI-46CRI-46A; RI-46B; RI-46C
RI-46A; RI-46B; RI-46C
Life expectancy: min. 2.5 x 10
7
operations with a failure
rate of less than 10
-8
with a confidence level of 90%.
End of life criteria:
Contact resistance > 2 W after 2.5 ms
Release time > 2.5 ms (latching or contact sticking).
Dimensions in inches (mm)
69
Catch Us on the Web! www.cotorelay.com E-Mail us: sales@cotorelay.com
RI-46 Series
Switching different loads involves different life expectancy
and reliability data. Further information is available on
request.
MM
MM
M
ECHANICALECHANICAL
ECHANICALECHANICAL
ECHANICAL
D D
D D
D
AA
AA
A
TT
TT
T
AA
AA
A
Contact arrangement is normally open; lead finish is tinned;
net mass is approximately 0.28 g; and can be mounted in
any position.
SS
SS
S
HOCKHOCK
HOCKHOCK
HOCK
The switches are tested in accordance with “IEC 68-2-27”,
test Ea (peak acceleration 500 G, half sinewave; duration
11 ms). Such a shock will not cause an open switch (no
magnetic field present) to close, nor a switch kept closed by
an 80 AT coil to open.
VV
VV
V
IBRAIBRA
IBRAIBRA
IBRA
TIONTION
TIONTION
TION
The switches are tested in accordance with “IEC 68-2-6”,
test Fc (acceleration 10 G; below cross-over frequency 57
to 62 Hz; amplitude 0.75 mm; frequency range 10 to 2000
Hz, duration 90 minutes). Such a vibration will not cause
an open switch (no magnetic field present) to close, nor a
switch kept closed by an 80 AT coil to open.
MM
MM
M
ECHANICALECHANICAL
ECHANICALECHANICAL
ECHANICAL
S S
S S
S
TRENGTHTRENGTH
TRENGTHTRENGTH
TRENGTH
The robustness of the terminations is tested in accordance
with “IEC 68-2-21”, test Ua
1
(load 40 N).
OO
OO
O
PERATINGPERATING
PERATINGPERATING
PERATING
ANDAND
ANDAND
AND
S S
S S
S
TORAGETORAGE
TORAGETORAGE
TORAGE
T T
T T
T
EMPERATUREEMPERATURE
EMPERATUREEMPERATURE
EMPERATURE
Operating ambient temperature; min: -55°C; max: +125°C.
Storage temperature; min: -55°C; max: +125°C.
Note:Note:
Note:Note:
Note: Temperature excursions up to 150°C may be permis-
sible. For more information contact your nearest Coto
Technology sales office.
SS
SS
S
OLDERINGOLDERING
OLDERINGOLDERING
OLDERING
The switch can withstand soldering heat in accordance with
“IEC 68-2-20”, test Tb, method 1B: solder bath at 350
±10°C for 3.5 ±0.5 s. Solderability is tested in accordance
with “IEC 68-2-20”, test Ta, method 3: solder globule
temperature 235°C; ageing 1b: 4 hours steam.
WW
WW
W
ELDINGELDING
ELDINGELDING
ELDING
The leads can be welded.
MM
MM
M
OUNTINGOUNTING
OUNTINGOUNTING
OUNTING
The leads should not be bent closer than 1 mm to the glass-
to-metal seals. Stress on the seals should be avoided. Care
must be taken to prevent stray magnetic fields from influ-
encing the operating and measuring conditions.
Note 1: Switching higher currents is possible depending on signature of the load.
Model Number
RI-46AA RI-46A RI-46B RI-46C
Parameters Test Conditions Units
Operating Characteristics
Operate Range AT 10.5-19 15-28 24-51 46-70
Release Range AT 4-12 5-16 8-20.5 12-22.5
Operate Time - including bounce (typ.) (energization) ms 0.35 (24 AT) 0.35 (35 AT) 0.35 (64 AT) 0.35 (87.5 AT)
Bounce Time (typ.) (energization) ms 0.15 (24 AT) 0.15 (35 AT) 0.15 (64 AT) 0.15 (87.5 AT)
Release Time (max) (energization)
µ
s
30 (24 AT) 30 (35 AT) 30 (64 AT) 30 (87.5 AT)
Resonant Frequency (typ.) Hz 3200 3200 3200 3200
Electrical Characteristics
Switched Power (max) W 30 30 40 40
Switched Voltage DC (max) V 200 200 200 200
Switched Voltage AC, RMS value (max) V 250 250 250 250
Switched Current DC (max)
note 1
mA 750 1000 1000 1000
Switched Current AC, RMS value (max)
note 1
mA 750 1000 1000 1000
Carry Current DC; AC, RMS value (max) A 2 2.5 3 3
Breakdown Voltage (min) V 300 400 580 780
Contact Resistance (initial max)
(energization)
m
90 (27 AT) 90 (27 AT) 90 (36AT) 90 (36 AT)
Contact Resistance (initial typ.)
(energization)
m
60 (27 AT) 60 (27 AT) 60 (36 AT) 60 (36 AT)
Contact Capacitance (max) without test coil pF 0.2 0.2 0.2 0.2
Insulation Resistance (min)
RH
45% M
10
6
10
6
10
6
10
6

RI-46A

Mfr. #:
Manufacturer:
Coto Technology
Description:
Magnetic / Reed Switches High power reed
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet