Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
EV (AEV)
ASCTB233E 201209-T
REFERENCE DATA
1.-(1) Ambient temperature characteristics
(10 A type)
Sample: EV relay 10 A, 3 pcs.
1.-(2) Ambient temperature characteristics
(20 A type)
Sample: EV relay 20 A, 3 pcs.
1.-(3) Ambient temperature characteristics
(80 A type)
Sample: EV relay 80 A, 3 pcs.
Pick-Up
voltage
Drop-out
voltage
Variation
ratio, %
-40
-20
-30
-10
-20
-40
X
X
0
40 60 80
Ambient
temperature, °C
40
30
20
10
20
Variation
ratio, %
-40
-20
-30
-10
-20
-40
0
40 60 80
Ambient
temperature, °C
40
30
20
10
Drop-out
voltage
Pick-Up
voltage
20
Variation
ratio, %
-40
-20
-30
-10
-20
-40
0
40 60 80
Ambient
temperature, °C
40
30
20
10
Pick-Up
voltage
Drop-out
voltage
20
1.-(4) Ambient temperature characteristics
(120 A type)
Sample: EV relay 120 A, 3 pcs.
1.-(5) Ambient temperature characteristics
(200 A type)
Sample: EV relay 200 A, 3 pcs.
1.-(6) Ambient temperature characteristics
(300 A type)
Sample: EV relay 300 A, 3 pcs.
Variation
ratio, %
-40
-20
-30
-10
-20
-40
0
40
20 60 80
Ambient
temperature, °C
40
30
20
10
Drop-out
voltage
Pick-Up
voltage
Variation
ratio, %
-40
-20
-30
-10
-20
-40
-50
0
40
20 60 80
Ambient
temperature, °C
40
50
30
20
10
Drop-out voltage
Pick-Up voltage
Variation
ratio, %
-40
-20
-30
-10
-20
-40
04020 60 80
Ambient
temperature, °C
40
30
20
10
Pick-Up
voltage
Drop-out
voltage
2. Max. value for switching capacity
When 400 V DC resistive load
3. Switching life curve (Forward direction)
When 400 V DC resistive load
4. Cut-off life curve (Forward direction)
Contact voltage, V
Contact current, A
110100 1000
1000
100
10
1
300 A type
120 A type
80 A type
10 A type
20 A type
200 A type
Contact current, A
Life, cycle
1
1
10
100
1000
10000
100000
10 100 1000
10 A type
80 A type
120 A type
300 A type
200 A type
20 A type
Life, cycle
Cut-off current, A
100 1000 10000
120 A type,
400 V DC
resistive load
(for Min. 600 A,
300 V DC)
200 A type,
400 V DC resistive load
(for Min. 900 A, 350 V DC)
300 A type,
400 V DC resistive load
(for Min. 900 A,
300 V DC)
80 A type,
400 V DC resistive load
(for Min. 600 A,
300 V DC)
1000
100
10
1
5. Carrying performance curve (80°C 176°F)
*For 200 A and 300 A, at 85°C 185°F
Time, sec
Carrying current, A
10
5
10
4
1000
100
10
110100 1000
120 A type
300 A type
200 A type
20 A type
10 A type
80 A type