ICS551
1 TO 4 CLOCK BUFFER FAN OUT BUFFER
IDT™
1 TO 4 CLOCK BUFFER 3
ICS551 REV P 051310
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS551. These ratings, which
are standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the
device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Recommended Operation Conditions
Item Rating
Supply Voltage, VDD 7 V
All Inputs and Outputs -0.5 V to VDD+0.5 V
Ambient Operating Temperature, Commercial 0 to +70° C
Ambient Operating Temperature, Industrial -40 to +85° C
Storage Temperature -65 to +150° C
Junction Temperature 125° C
Soldering Temperature 260° C
Parameter Min. Typ. Max. Units
Ambient Operating Temperature -40 – +85 ° C
Power Supply Voltage (measured in respect to GND) +3.0 +5.5 V