1311-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
DTM65-C Series
Features
CEC, EISA
(1)
& ErP Stage 2 Compliant
Wide Range AC Input
Medical Certifi cations
85% Effi cient, >87% average (12V models & above)
40-65W Medical AC-DC External Power Supplies
Model
Input Voltage range VAC 90 - 264VAC (47 - 63Hz)
Inrush Current A <100A at 230VAC input, 25°C ambient cold start
Input Current A 2A at 90VAC, Full Load
Power Factor - Meets EN61000-3-2 Class A
Leakage Current (264VAC 63Hz) μA <300uA
Hold Up Time (Typ) ms 16ms at 115VAC input
Temperature Coeffi cient - ±0.05%/°C
Voltage Accuracy % ±1%
Adjustment Range - None
Minimum Load A None
Total Regulation - 5V to 15V Models: ±5%, >15V models ±3%
Ripple & Noise % 1% or 100mV whichever is the greater
Short Circuit Protection - Continuous - hiccup mode
Overvoltage Protection V 110 - 150% of nominal (Cycle input power to reset)
Effi ciency % >87%, average effi ciency for 12V and greater models, >75% <12V models
Operating Temperature - 0 to +50°C
Storage Temperature - -10 to +70°C
Humidity (non condensing) - 10 - 90% RH
Cooling - Convection
Withstand Voltage - Input to Ground 1.5kVAC, Input to Output 4kVAC (Reinforced)
(2 x MOPPS 3rd Edition) (Output is connected to Ground)
Vibration (non operating) - 23.52m/s
2
(10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
Shock - < 196.1 m/s
2
(20G)
Safety Agency Approvals - UL/CSA/IEC/EN 60601-1, ANSI/AAMI ES60601-1, CE Mark
California Energy Commission (CEC) - See model selector
EISA - See model selector
Offl oad Power Consumption - < 0.5W
Conducted & Radiated EMI - EN55011, EN60601-1-2 Class B
Immunity - EN55011: 2007 +A2: 2007
Weight (Typ) g 460g
Size (WxLxH) in 2.72 x 5.2 x 1.57
Cable Length mm 1050mm
AC Input Connector - IEC 320-C14 (Accepts IEC 320-C13)
Output Connector - Kycon KPPx-4P or equivalent, Pins 1 & 2: -Vout, Pins 3 & 4: +Vout
Warranty yrs Two Years
Specifi cations
(1) EISA - Energy Independence and Security Act of 2007
Key Market Segments & Applications