Surge arrester B88069X9170B152
2-electrode arrester V10-H08X
PPD AB PD / PPD AB PM Version: 05 / 2018-02-24
Please read Cautions and warnings and Page 2 of 5
Important notes at the end of this document.
Features Applications
Standard size
Maximum current rating
Fast response time
Stable performance over life
High insulation resistance
RoHS-compatible
Industry
Electrical specifications
DC spark-over voltage
1) 2)
Tolerance
Min.
Max.
800
±20
640
960
V
%
V
V
Impulse spark-over voltage
at 100 V/µs - for 99% of measured values
- typical values of distribution
at 1 kV/µs - for 99% of measured values
- typical values of distribution
< 1000
< 900
< 1200
< 1100
V
V
V
V
Service life
10 operations 50 Hz, 1 s 20 A
1 operations 50 Hz, 0.18 s (9 cycles) 120 A
10 operations 8/20 µs 20 kA
1 operation 8/20 µs 30 kA
1 operation 10/350 µs 5 kA
Insulation resistance at 100 V
DC
> 1
GΩ
Capacitance at 1 MHz < 1.5 pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 35
< 1
~ 200
V
A
V
Weight ~ 8 g
Operation and storage temperature
−40 ... +125
°C
Climatic category (IEC 60068-1) 40/125/21
Marking, black positive
800 YY O
800 - Nominal voltage
YY - Year of production
O - Non radioactive
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
Terms in accordance with ITU-T Rec. K.12 and IEC 61643-311.