Summary:
The data in the tables that follow was generated as the result of an on-going Process Reliability
Monitor. The specific products in this process monitor are:
The calculated failure rate for devices using this process is:
The reliability data follows and in this section is the detailed reliability data by stress. The reliability
data section includes the latest data available. This report covers data between
and .
10/1/2011
9/30/2012
The parameters used to calculate this failure rate are as follows:
Cf: 60% Ea: 0.7 Tu: 25
°C
Process Description: San Antonio 0.4µm Silicon Gate CMOS (S4)
Process Information:
MAX11040GUU MAX13325GUI/ MAX13326GUI/ MAX13335EGEE MAX13362ATL/
MAX13366GTE/ MAX14522AEZ MAX15021ATI+ MAX15022ATI+ MAX15026BET
MAX15029AGA/ MAX16128UAA MAX16814AUP/ MAX16822AAS MAX16833AUE/
MAX16833CAU MAX16833FAU MAX16834ATP+ MAX16903SAU MAX16908RAU
MAX16916GUB/ MAX16917BGE MAX16922ATPF MAX16924GGM MAX16924GTM/
MAX16941AUE/ MAX16942EGEE MAX16946GTE/ MAX16946GTE+ MAX16948AGT
MAX16952AUE/ MAX16969DGE MAX16980GEE/ MAX16981GEE/ MAX17018DAT
MAX17094ETM MAX17114ETM MAX34565 MAX4967EGEE/ MAX5112GTJ+
MAX5316GTG+ MAX5971BETI+ MAX5982BETE+ MAX6070AAUT MAX6070BAUT
MAX77100EWL MAX8643ETG+ MAX8795AGTJ/ MAX8795AGTJ+ MAX8798AETX
MAX8899EWZ+ MAX8904ETN+ MAX8939EWV+ MAX9736AETJ+ MAX9736BETJ+
MA
X9737ETG+ MAX9739ETG+ MAX9924UAUB
FITS: 0.4MTTF (YRS): 240723FAILURE RATE: QUANTITY: 2377 FAILS: 0
OPERATING LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
TEST
VEHICLE
LOT
NO.
192135°C 43 0HIGH TEMP OP LIFE HRS1007 MAX8904ETN+ TQIZGQ003DQ
500135°C 48 0HIGH TEMP OP LIFE HRS1017 MAX13326GUI/V+ TZYYBQ002H
1000135°C 47 0HIGH TEMP OP LIFE HRS1052 MAX17114ETM+CB2 TURZEA282AB
1000135°C 90 0HIGH TEMP OP LIFE HRS1103 MAX4967EGEE/V+ TKWZCA015BD
1000135°
C 78 0HIGH TEMP OP LIFE HRS1105 MAX16924GTM/V+ TYUZFQ003DE
1000135°C 85 0HIGH TEMP OP LIFE HRS1105 MAX16908RAUE50/V+ TTDYCQ003F#
500135°C 47 0HIGH TEMP OP LIFE HRS1109 MAX8939EWV+ TE0ZCQ002BQ
1000135°C 75 0HIGH TEMP OP LIFE HRS1109 MAX16924GTM/V+ TYUZFQ003D
192135°C 48 0HIGH TEMP OP LIFE HRS1120 MAX5982BETE+ T2CZAQ001CQ
500135°
C 26 0HIGH TEMP OP LIFE HRS1124 MAX16941AUE/V+ TXNZCQ001EA
192135°C 80 0HIGH TEMP OP LIFE HRS1128 MAX13335EGEE/+ TU8ZBQ001AQ
1000135°C 79 0HIGH TEMP OP LIFE HRS1130 MAX15029AGA/VY+ TJXXDQ001UV
1000135°C 80 0HIGH TEMP OP LIFE HRS1131 MAX16969DGEE/V+ TR1ZBQ003AK
1000135°C 80 0HIGH TEMP OP LIFE HRS1137 MAX8798AETX+ TRIZG2026N