RV-3.312S/P

Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
2 Watt DIP24
Miniature
Single
& Dual
Output
UL/CSA and EN-60950-1 Safety certified
EN-60601 for Medical Applications
6kVDC Isolation
Optional Continuous Short Circuit Protection
Efficiency up to 82%
Space Saving „Skinny DIP“ Package
Very Low Isolation Capacitance
Suitable for IGBT Applications
Features
Unregulated
Converters
Selection Guide
Output Power (%)
100
60
20
40
100500-40
90
150
Operating Temperature °C
0
80
Safe Operating Area
95
Derating-Graph
(Ambient Temperature)
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 3.3V output types 20% max.
(10% to 100% full load) 5V output type 15% max.
9V, 12V, 15V, 24V output types, RV-xx1509D 10% max.
Output Ripple and Noise (20MHz limited) 200mVp-p max.
Operating Frequency 20kHz min. / 50kHz typ. / 85kHz max.
RV-xx1509D 20kHz min. / 47kHz typ.
Efficiency at Full Load 70% min. / 75% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage (tested for 1 second) 6000VDC
(rated for 1 minute**) 3000VAC / 60Hz
Isolation Capacitance 2pF min. / 12pF max.
Isolation Resistance 15 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection, without derating) -40°C to +90°C (see Graph)
Storage Temperature Range -55°C to +125°C
continued on next page
Description
Very high isolation in a small size are the main features of this miniature DIP24 converter,
ideal for highly sophisticated industrial, test and measurement and medical designs where
board space is at a premium.
RV
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Refer to Application Notes
E358085
RoHS
2011/65/EU
6/6
Part Input Output Output Efficiency Max
Number Voltage Voltage Current Std Capacitive
SIP 7 (VDC) (VDC) (mA) (%) Load
(1)
RV-xx3.3S* 3.3, 5, 12, 15, 24 3.3 600 70 3300µF
RV-xx05S* 3.3, 5, 12, 15, 24 5 400 70-75 1200µF
RV-xx09S* 3.3, 5, 12, 15, 24 9 222 70-75 1200µF
RV-xx12S* 3.3, 5, 12, 15, 24 12 167 70-75 680µF
RV-xx15S* 3.3, 5, 12, 15, 24 15 132 75-80 680µF
RV-xx24S* 3.3, 5, 12, 15, 24 24 83 75-80 220µF
RV-xx3.3D* 3.3, 5, 12, 15, 24 ±3.3 ±300 70 ±1500µF
RV-xx05D* 3.3, 5, 12, 15, 24 ±5 ±200 70-75 ±470µF
RV-xx09D* 3.3, 5, 12, 15, 24 ±9 ±111 70-75 ±470µF
RV-xx12D* 3.3, 5, 12, 15, 24 ±12 ±85 70-75 ±220µF
RV-xx15D* 3.3, 5, 12, 15, 24 ±15 ±66 75-80 ±220µF
RV-xx24D* 3.3, 5, 12, 15, 24 ±24 ±42 75-80 ±100µF
RV-xx1509D 5, 12, 24 +15/-9 +67/-111 70-82 ±330µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
RV-0505S/P, RV-0505D/P
EN-60950-1 Certified
IEC/EN-60601-1 Certified*
UL/CSA 60950-1 Certified*
* +15/-9 Version excluded
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
REV: 0/2015 E-109www.recom-power.com
RV
Typical Characteristics
ECONOLINE
DC/DC-Converter
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
1205
0505
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
1212
0512
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0505
0.000
5.000
10.000
15.000
20.000
25.000
1205
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0512
0.000
5.000
10.000
15.000
20.000
25.000
1212
RV-xx05S
RV-xx12S
Relative Humidity 95% RH
Package Weight 9g
Packing Quantity 15 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 1154 x 10
3
hours
(+85°C) using MIL-HDBK 217F 168 x 10
3
hours
Certifications UL/cUL General Safety Report: E358085 UL 60950-1 2nd Ed.
EN General Safety Report: SPCLVD1109103 EN60950-1:2006 + A12: 2011
EN Medical Safety Report: SPCMDD1205098-4 IEC/EN60601-1:2006, 3rd Edition
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up))
Tolerance Envelope
+10%
+6%
V Nom.
+5%
 2.5%
10% 50% 100%
Output Voltage
Output Load Current (%)
 5%
Typical Load Line
}
Detailed Information see
Application Notes chapter "MTBF"
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
RV
Series
REV: 0/2015 www.recom-power.comE-110
RV
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
1212
0512
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0512
0.000
5.000
10.000
15.000
20.000
25.000
1212
RV-xx12D
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0505
0.000
5.000
10.000
15.000
20.000
25.000
1205
RV-xx05D
RV
Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
Isolated
DC/DC
Converter
IGBT
Driver
IGBT
Rg
+Vout
-Vout
Control Signal
-Vin
C1
C2
C3
+
+
+
1
2
7
6
5
IGBT Application
Circuit
Applications
REV: 0/2015 E-111www.recom-power.com

RV-3.312S/P

Mfr. #:
Manufacturer:
RECOM Power
Description:
Isolated DC/DC Converters 2W DC/DC MIN 6kV UNREG 3.3Vin 12Vout
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union