GPFC110-5G

• 3.1 watts/cu.in. power density
• Compact size (6.3” x 3.75” x 1.62”;
meets 1U height)
• Power factor corrected to IEC 1000-3-2 Class A
• Less than 300 μA leakage
• EMI compliance to CISPR 22, FCC Class B
• Approved to UL1950, IEC950 and
CSA 22.2 No. 950
• 2-year warranty
• RoHS Compliant Model Available (G sux)
GPFC110 Commercial
110 Watt Global Performance Switchers
110 WATT GLOBAL PERFORMANCE SWITCHERS
FEATURES:
All specications are typical at nominal input, full load at 25
O
C unless otherwise stated
EMI/EMC Compliance
All models include built-in EMI ltering to meet the EMC requirements below.
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current 2.3 A at 90 Vac, 60 Hz with full rated load. Input cur-
rent harmonic content meets the requirements of IEC1000-3-2.
Hold-up Time
25 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Output Power
110 W fan cooled, 75 W convection. Peak ratings are for 60 s maximum dura-
tion, 10% duty cycle.
Total Regulation
Total regulation is the maximum deviation from the nominal voltage for all
steady-state loading conditions.
Overload Protection
Fully protected against short circuit and output overload. Short circuit protec-
tion is cycling type power limit. Recovery after fault is automatic.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz Bandwidth, dierential mode. Measured with
noise probe directly across output terminals of the power supply.
Transient Response
500 μs typical response time for return to within 0.5% of nal value for a 50%
load step change, ∆i/∆ t< 0.2 A/μs. Maximum voltage deviation is 3.5%. Load
must not go below stated minimum.
Remote Sense
Provided as a standard feature. Capable of compensating for 0.25 V total of
cabling losses in voltage. Open sense lead protection.
Overvoltage Protection
OVP crowbar reduces output voltage below nominal rating in less than 50 ms.
Voltage Adjustment: Main output ±5%.
Input Protection
Internal ac fuse provided on all models. Fuse does not blow on overload or
short circuit—fuse blows only if catastrophic failure occurs in the unit.
EMI SPECIFICATIONS COMPLIANCE LEVEL
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
Line Frequency Harmonics
EN55022 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV di., 2 kV com.
EN61000-3-2 Class A
SPECIFICATIONS
Inrush Current
Inrush 240 Vac is less than 37 A, averaged over the rst ac half-cycle under cold
start conditions. Limiting provided by internal thermistors.
Fan Output
An additional output, same as Vout, suitable for powering a dc fan is included in all
models. The output is protected by an internal resistor in the event of an overload.
Power Fail
TTL or CMOS compatible output goes low (<0.5 V) 8 ms before output voltage
drops more than 4% below nominal voltage upon loss of ac power. The signal is
factory set to trip when input power can no longer sustain the output.
Temperature Coecient
0.03%/°C typical on all outputs.
Environmental
Designed for 0 to 50°C operation at full rated output power; derate output current
and total output power by 2.5% per °C above 50°C. See Environmental and Pack-
aging Specications on the next page.
Commercial Safety Approvals
All models are approved to UL1950, CSA22.2 No. 950-95, IEC950, EN60950. CB
certicate available. Exceeds FCC and CISPR22 Class B conducted emissions
requirement
• marked to LVD
SL Power Electronics., 6050 King Drive, Bldg A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com Rev. 8/12 Data Sheet © 2009
SL Power Electronics Inc. The information and specications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specications are subject to change without notice.
GPFC110 MECHANICAL SPECIFICATIONS
Notes:
A. With unrestricted convection cooling.
B. With 26cfm airow.
C. Add “G” sux to part number for RoHS compliant model.
Commercial
Model Output No. Output
Output
Minimum (A)
Output
Maximum (A)
Output
Maximum (B)
Total
Regulation OVP Setpoint Notes
GPFC 110-5 1 5.1 v 0 A 11 A 15 A 2% 6.2 ± 0.6 V C
GPFC 110-12 1 12 V 0 A 6.7 A 9.2 A 2% 14 ± 1.1 V C
GPFC 110-15 1 15 V 0 A 5.3 A 7.3 A 2% 18.5 ± 1.5 V C
GPFC 110-24 1 24 V 0 A 3.4 A 4.6 A 2% 28 ± 2.5 V C
GPFC110-28 1 28 V 0 A 2.9 A 3.9 A 2% 34 ± 2.8 V C
GPFC110-48 1 48 V 0 A 1.7 A 2.3 A 2% 55 ± 4 V C
ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING
Temperature (A) See Individual Specs. -40 to +85°C
Humidity (A) 0 to 95% RH 0 to 95% RH
Shock (B) 20 g
pk
40 g
pk
Altitude -500 to 10,000 ft -500 to 40,000 ft
Vibration (C) 1.5 g
rms’
0.003 g
2
/Hz
5 g
rms’
0.026 g
2
/Hz
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power.
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction,
3 orthogonal axes, total 6 shocks.
C. Random vibration—10 to 2000Hz, 6dB/octave roll-o from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and
1 hr./axis non-operating.

GPFC110-5G

Mfr. #:
Manufacturer:
Condor / SL Power
Description:
Switching Power Supplies 110W 5.1V @ 11A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union