PR02-FS
www.vishay.com
Vishay BCcomponents
Revision: 15-Feb-17
5
Document Number: 28915
For technical questions, contact: filmresistorsleaded@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Pulse performance after a rectangular pulse of defined duration is applied
TESTS PROCEDURES AND REQUIREMENTS
All tests are carried out in accordance with the following
specifications:
• IEC 60115-1, generic specification (includes tests)
The test and requirements table contains only the most
important tests. For the full test schedule refer to the
documents listed above.
The tests are carried out in accordance with IEC 60068-2-xx
test method and under standard atmospheric conditions in
accordance with IEC 60068-1, 5.3.
Climatic category LCT / UCT / 56 (rated temperature range:
lower category temperature, upper category temperature;
damp heat, steady state, test duration: 56 days) is valid.
Unless otherwise specified the following values apply:
• Temperature: 15 °C to 35 °C
• Relative humidity: 25 % to 75 %
• Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar)
For performing some of the tests, the components are
mounted on a test board in accordance with IEC 60115-1,
4.31.
In test procedures and requirements table, only the tests
and requirements are listed with reference to the relevant
clauses of IEC 60115-1 and IEC 60068-2-xx test methods.
A short description of the test procedure is also given.
Pulse Duration (s)
Peak Power in W
1
10 000
10
100
1000
10
-1
10
-3
10
-4
10
0
10
-2
10
-5
10
1
TEST PROCEDURES AND REQUIREMENTS
IEC
60115-1
CLAUSE
IEC
60068-2-
TEST
METHOD
TEST PROCEDURE
REQUIREMENTS PERMISSIBLE
CHANGE
(R
max.
)
4.4.1 - Visual examination No holes; clean surface; nodamage
4.4.2 - Dimensions (outline) Gauge (mm) SeeDimensions table
4.5 - Resistance
± 10 % R
± 20 % R
4.6.1.1 - Insulation resistance
500 V after 1min;
metal block method
R
ins min.
: 10
4
M
4.7 - Voltage proof U
ins
= 500 V
RMS
; 60 s No breakdown or flashover
4.8 -
Temperature
coefficient
At (20 / -55 / 20) °C
and (20 / 155 / 20) °C
± 250 ppm/K
4.16
21 (Ua
1
)
21 (Ub)
21 (Uc)
Robustness of
terminations
Tensile, bending, and torsion
No damage
R
max.
:± (0.5 %R +0.05)