DS9107+

19-4880; Rev
11/09
DS9107
1 of 3
DESCRIPTION
The iButton Capsule is a mechanical enclosure to
protect Temperature Logger i
Buttons (DS1921 and
DS1922 series) from moisture, solvents and
pressure. It provides IP68 protection to the i
Button
inside (refer to Application Note 4126: Understanding
the IP (Ingress Protection) Ratings of iButton Data
Loggers and Capsule). The protection level exceeds
the “Water Resistant 3 ATM” requirements.
The DS9107 consists of a base with the cavity for a
F5 i
Button, a screw-in plug with O-ring to seal the
enclosure, and a top with two stainless-steel screws
to mount the i
Button Capsule to a cable, e.g., to
measure temperature at different levels within a
liquid. The cable is inserted into the notch of the plug
where it is held in place by the matching protrusion of
the top piece.
Base, plug, and top are made of polyphenylene
sulfide (PPS). This material is chosen for its
mechanical properties (remains stable during both
long and short-term exposure to high temperatures),
inherent flame resistance, and outstanding chemical
resistance (inert to steam, strong bases, fuels and
acids). Although PPS is virtually insoluble below
200°C, it can be attacked by chlorinated
hydrocarbons. The silicone O-ring matches the
temperature and chemical qualities of the PPS. In
addition, it is resistant to sunlight, ozone, oxygen,
and UV light. The chemical stability of the screws
does not compromise that of the PPS and the
silicone.
APPLICATIONS
Autoclave Sterilization
Seawater temperature profiling
Monitoring of beverage production
Scientific research
ORDERING INFORMATION
PART DESCRIPTION
DS9107+ iButton Capsule
+Denotes a lead(Pb)-free/RoHS-compliant product.
TECHNICAL DRAWING
5.12.54
3.3
25.4
25.4
6.35
12.7
25.4
6.35
16.5
22.2
To
p
Plu
g
O-Ring
Base
Cavity for
F5-size
i
Button
Notch
Protrusion
Screws
All dimensions are in millimeters.
iButton Capsule
www.maxim-ic.com
iButton is a registered trademark of Maxim Integrated Products, Inc.
DS9107: iButton Capsule
2 of 3
ABSOLUTE MAXIMUM RATINGS
Temperature Range -40°C to +140°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is
not implied. Exposure to the absolute maximum rating conditions for extended periods may affect device.
SPECIFICATIONS
PARAMETER CONDITIONS MIN TYP MAX UNITS
Weight Empty 18.4 grams
Physical Dimensions See technical drawing mm
Torque for Tightening the Plug (Note 1) 36.5 Nm
Number of Open/Close Cycles Maximum torque applied 500
Number of Autoclave Cycles
From 25°C @ 101.3kPa (14.7psia) to
121°C @ 205kPa (29.7psia), tightened
to maximum torque (Note 2)
100
Thermal Response Time
Constant
(Note 3) 150 s
Note 1:
Equivalent to 2.5ft/lbs.
Note 2:
Absolute pressure is specified; the autoclave peak pressure is 103.4 kPa (15 psig) above the standard
atmospheric pressure.
Note 3:
The value was derived from submerging an i
Button capsule with DS1922T inside into 55°C water. The
initial temperature of i
Button and capsule was 23.5°C. Without capsule, the response time constant is
approximately 30s. Do not drop an unprotected i
Button into water or any other liquid.
Top, Plug, Base
Material: Polyphenylene sulfide (PPS Ryton) with black flat finish, electrically non-conductive.
The injection molding compounds (Ryton® PPS) used in the DS9107 are subject to the general safety provisions of
the U.S. Food, Drug and Cosmetic Act. It is the responsibility of the purchaser/user of the DS9107 i
Button Capsule
to determine the safety and suitability of the injection molding compounds for their specific application.
O-Ring
Material: S500-70 Silicone Compound, orange, FDA approved.
Replacement O-Rings: Size AS568-019, inner diameter 13/16 inch, outer diameter 15/16 inch, cross section 1/16
inch, nominal values.
Screws
Material: Type 303 austenitic stainless-steel.
Replacement Screws: flat-head Phillips countersunk, self-tapping, M2.3, 9mm long.
APPLICATIONS INFORMATION
The iButton is inserted into the base part with the data contact towards the bottom of the base. The plug is then
placed into the base and initially tightened by hand. Then the base is held with a wrench, and using a metal stick
inserted horizontally into the notch of the plug, the plug is tightened until its head touches the top of the base. It is
important not to exceed the maximum permissible torque.
The i
Button Capsule does not provide electrical contact to the iButton inside. Therefore it is necessary to setup
(mission) the temperature logger first before inserting it into the i
Button Capsule. To download the logged
temperature data, the logger needs to be taken out of the i
Button Capsule.
Ryton is a registered trademark of Chevron Phillips Chemical Company LP.
DS9107: iButton Capsule
3 of 3
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim
reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2009 Maxim Integrated Products Maxim is a registered trademark of Maxim Integrated Products, Inc.
REVISION HISTORY
REVISION
DATE
DESCRIPTION
PAGES
CHANGED
8/09
Added the + sign to the PART number in the Ordering Information table, indicating
a lead(Pb)-free/RoHS-compliant package.
1
Added a reference to the device’s ingress protection rating and Application Note
4126.
1
11/09
Added statement to Note 3: “Do not drop an unprotected i
Button into water or any
other liquid.”
2

DS9107+

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
iButtons & Accessories iButton Capsule
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet