Q4015L5

Thermal Automotive Circuit Breaker 1160-...
www.e-t-a.de
1646 1
Description
Typical applications
Ordering information
Standard current ratings and typical voltage drop values
Technical data
Thermal circuit breaker, with controlled self-resetting mechanism,
specially suited to installation in inaccessible locations. Under overload
conditions the circuit breaker contacts will open to protect the load
circuit. A low current excitation circuit ensures that the contacts remain
open thereby avoiding the hazards of automatic reset operation. The
circuit breaker is reset by switching off the supply circuit for a short
period. Class 2 device, contacts stay open until voltage is removed.
Type II to SAE J 553.
Automotive and marine extra low voltage wiring systems and components,
battery powered appliances.
1160-...
Voltage rating DC 12 V
Current ratings 12...30 A
Typical life 300 operations at 2 x I
N
Ambient temperature -30...+60 °C (-22...+140 °F)
Holding current < 0.6 A
Reset time at 23°C after
5 s of load with U
N
< 35 sec
Interrupting capacity
(o-o-o) 200 A, L/R = 2.5 ms
Degree of protection housing area IP54
(IEC 60529/DIN 40050) terminal area IP00
Vibration 5 g (57-500 Hz) ± 0.38 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
Shock 25 g (11 ms)
to IEC 60068-2-27, test Ea
Corrosion 96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity 240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass approx. 6 g
Type No.
1160 single pole plug-in type
Design standard
02 standard version 12 V
Current ratings
12, 15, 20, 30 A
1160 - 02 - 12A ordering example
Current rating (A) Voltage drop (mV)
12 < 150
15 < 150
20 < 150
30 < 150
1
Thermal Automotive Circuit Breaker 1160-...
www.e-t-a.de
16462
1
The time/current characteristic curve depends on the ambient temperature
prevailing. In order to eliminate nuisance tripping, please multiply the
circuit breaker current ratings by the derating factor shown below. See also
section Technical information.
Ambient temperature °F
°C
-4
-20
+14
-10
+32
0
+73.4
+23
+104
+40
+122
+50
+140
+60
Derating factor
0.76 0.84 0.92 1 1.08 1.16 1.24
124
6
81020
40
Trip time in seconds
... times rated current
10000
1000
100
10
1
0.1
0.6 0.8
.988
.937
.366
.205
.098
.031
.299
.087
.362
.390
.689
23.8
25.1
9.3
5.2
17.5s
2.2
7.6
2.5
0.8
9.2
9.9
1
2
Dimensions
Accessories
Internal connection diagram
Typical time/current characteristics at +23 °C/+73.4 °F
Sockets available to special order.
This is a metric design and millimeter dimensions take precedence (
mm
)
inch
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.

Q4015L5

Mfr. #:
Manufacturer:
Littelfuse
Description:
Triacs 400V 15A 50-50-50mA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet