Input Fuse is recommended. Recommended fuse rating = double maximum input current, time delay type.
Input Capacitor, C1, is required to meet EN61000 Surge and Fast Transient, otherwise it is not required for normal operation.
Output Capacitors C2/C3 are recommended, but not required for normal operation. Typical capacitor values are 1µF MLCC
To ensure optimum thermal performance, use large areas of copper on the PCB to assist with heat dissipation and mount the converter vertically.
C1
Fuse
C3
No tracks
in this area
(42 x 30mm)
Top View
C3
C2
Baseplate Case- suggested PCB layout
Ribbed Case (Standard - no suffix)
Dual OutputSingle Output
Recommended PCB Layout
PP-12www.recom-power.comREV: 0/2014
RPP20-W
POWERLINE+
DC/DC-Converter
RPP20-S_DW
Series
Package Style and Pinning (mm)
3
1
2
5
4
17.8
dia.
1.0
10.20
36.0
50.8
Bottom View
6
1.7
4.0
8.7
17.8
25.4
45.7
6x 3.55
(use M3
screws)
5.10
40.6
10.20
10.20
30.9
2.8
11.4
2.54
32.6
3.3
3.0
1.0
38.0*
*Recommended Fixing Centres
Pin Pitch Tolerance ±0.35 mm
Pin Connections
Pin # Single Dual
1 +Vin +Vin
2 -Vin -Vin
3 +Vout +Vout
4 -Vout Com
5 Trim -Vout
6 CTRL CTRL
Baseplate Case (-B Suffix)
Use 10mm
Spacers
PCB
PCB
Baseplate Case Fixing - Mounting onto Heatsink/Bulkhead
Baseplate Case Fixing - Anti Vibration Mounting onto PCB
NOTE:
Pin separation is different
between ribbed and baseplate
versions.
The product information and specifications are subject to change without prior notice. All products are designed for non-safety critical commercial and industrial applications.
The Buyer agrees to implement safeguards that anticipate the consequences of any failures that might cause harm, loss of life and/or damage property.