DG2535DQ-T1-E3

www.vishay.com
4
Document Number: 72939
S-71009-Rev. E, 14-May-07
Vishay Siliconix
DG2535/DG2536
TYPICAL CHARACTERISTICS 25 °C, unless otherwise noted
r
ON
vs. V
COM
and Supply Voltage
Supply Current vs. Temperature
Leakage Current vs. Temperature
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
V
COM
- Analog Voltage (V)
T = 25 °C
I
A
= 100 mA
- On-Resistance (Ω)
r
ON
V+ = 1.8 V
V+ = 2.0 V
V+ = 2.7 V
V+ = 3.0 V
V+ = 3.3 V
10
10000
100000
Temperature (
°C)
100
1000
I+ - Supply Current (nA)
V+ = 3.0 V
V
IN
= 0 V
- 60 - 40 - 20 0 20 40 60 80 100
1
10000
Temperature (
°C)
V+ = 3.0 V
100
1000
Leakage Current (pA)
I
COM(on)
I
NO(off)
, I
NC(off)
10
I
OM(off)C
r
ON
vs. Analog Voltage and Temperature (NC1)
Supply Current vs. Input Switching Frequency
Leakage vs. Analog Voltage
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.0 0.5 1.0 1.5 2.0 2.5 3.0
V
COM
- Analog Voltage (V)
- On-Resistance (Ω)
r
ON
V+ = 3.0 V
I
S
= 100 mA
85 °C
25 °C
- 40 °C
10 10 K 100 K 10 M100 1 K 1 M
100 mA
10 mA
1 mA
100 µA
10 µA
1 µA
100 nA
1 nA
Input Switching Frequency (Hz)
I+ - Supply Current (A)
V+ = 3 V
10 nA
- 300
- 250
- 200
- 150
- 100
-50
0
50
100
150
200
250
300
0.0 0.5 1.0 1.5 2.0 2.5 3.0
V
COM
- Analog Voltage (V)
Leakage Current (pA)
V+ = 3.0 V
I
COM(on)
I
COM(off)
I
NO(off)
, I
NC(off)
Document Number: 72939
S-71009-Rev. E, 14-May-07
www.vishay.com
5
Vishay Siliconix
DG2535/DG2536
TYPICAL CHARACTERISTICS 25 °C, unless otherwise noted
TEST CIRCUITS
Switching Time vs. Temperature
Switching Threshold vs. Supply Voltage
0
10
20
30
40
50
60
70
80
100
90
- 60 - 40 - 20 0 20 40 60 80 100
/t
ON
- Switching Time (ns)
t
OFF
t
ON
V+ = 3 V
t
OFF
V+ = 3 V
Temperature (°C)
t
ON
V+ = 2 V
t
OFF
V+ = 2 V
0.00
0.25
0.50
0.75
1.00
1.25
1.50
1.75
2.00
0123456
V+ - Supply Voltage (V)
- Switching Threshold (V)
V
T
Insertion Loss, Off-Isolation
Crosstalk vs. Frequency
Charge Injection vs. Analog Voltage
100 K
-90
10 M
10
-70
-50
100 M 1 G1 M
Frequency (Hz)
(dB)
Loss, OIRR, X
TALK
-30
-10
OIRR
X
TA L K
V+ = 3.0 V
R
L
= 50 Ω
Loss
- 300
- 250
- 200
- 150
- 100
-50
0
50
100
150
200
250
300
0.0 0.5 1.0 1.5 2.0 2.5 3.0
V
COM
- Analog Voltage (V)
Q - Charge Injection (pC)
V+ = 3.0 V
V+ = 2.0 V
Figure 1. Switching Time
Switch
Input
C
L
(includes fixture and stray capacitance)
V+
IN
NO or NC
C
L
35 pF
COM
Logic
Input
R
L
300 Ω
V
OUT
GND
V+
50 %
0 V
Logic
Input
Switch
Output
t
ON
t
OFF
Logic "1" = Switch On
Logic input waveforms inverted for switches that have
the opposite logic sense.
0 V
Switch Output
V
OUT
=V
COM
R
L
R
L
+R
ON
0.9 x V
OUT
t
r
< 5 ns
t
f
< 5 ns
V
INH
V
INL
www.vishay.com
6
Document Number: 72939
S-71009-Rev. E, 14-May-07
Vishay Siliconix
DG2535/DG2536
TEST CIRCUITS
Vishay Siliconix maintains worldwide manufacturing capability. Products may be manufactured at one of several qualified locations. Reliability data for Silicon Tech-
nology and Package Reliability represent a composite of all qualified locations. For related documents such as package/tape drawings, part marking, and reliability
data, see http://www.vishay.com/ppg?72939.
Figure 2. Break-Before-Make Interval
C
L
(includes fixture and stray capacitance)
NC
V
NO
NO
V
NC
0 V
Logic
Input
Switch
Output
V
O
V
NC
= V
NO
90 %
t
D
IN
COM
V+
GND
V+
C
L
35 pF
V
O
R
L
300 Ω
V
INL
V
INH
t
r
< 5 ns
t
f
< 5 ns
t
D
Figure 3. Charge Injection
C
L
= 1 nF
R
gen
V
OUT
COM
V
IN
= 0 - V+
IN
GND
V+
V+
+
NC or NO
Off
OnOn
IN
ΔV
OUT
V
OUT
Q = ΔV
OUT
x C
L
IN depends on switch configuration: input polarity
determined by sense of switch.
Figure 4. Off-Isolation
IN
GND
NC or NO
0 V, 2.4 V
10 nF
COM
Off Isolation = 20 log
V
COM
V
NO/ NC
R
L
Analyzer
V+
V+
COM
Figure 5. Channel Off/On Capacitance
NC or NO
f = 1 MHz
IN
COM
GND
0 V, 2.4 V
Meter
HP4192A
Impedance
Analyzer
or Equivalent
10 nF
V+
V+

DG2535DQ-T1-E3

Mfr. #:
Manufacturer:
Vishay / Siliconix
Description:
Analog Switch ICs RECOMMENDED ALT 78-DG2535EDQ-T1-GE3
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union