cui.com
CUI Inc │ SERIES: EPS 6W │ DESCRIPTION: AC-DC POWER SUPPLY date 04/18/2013 │ page 2 of 5
INPUT
parameter conditions/description min typ max units
voltage 100 132 Vac
frequency 47 63 Hz
current 0.15 A
inrush current
1
15V, 18V and 24V model
at 100 Vac
at 132 Vac
15
30
A
A
all other models at 132 Vac 40 A
no load power consumption
level IV models
level V models
0.5
0.3
W
W
Notes: 1. inrush lasts no longer than 0.5 ms before settling to steady state current
OUTPUT
parameter conditions/description min typ max units
line regulation
all other models
7.5V model
±1
±2
%
%
load regulation ±5 %
temperature coefcient 0 ~ 40°C, full load, after initial 1 hour warm-up ±0.02 %/°C
start-up time needed to reach regulation 3 s
hold-up at 115 Vac, full load 10 ms
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection clamped by internal protection zener
short circuit protection continuous, auto-recovery upon removal of short
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output at 10 mA for 1 minute
3,000
4,242
Vdc
Vdc
isolation resistance input to output at 500 Vdc 100
MΩ
safety approvals UL 1310
safety class II
EMI/EMC FCC Part 15 Class B
leakage current 0.25 mA
RoHS compliant yes
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 40 °C
storage temperature -10 70 °C
operating humidity 20 80 %
storage humidity 10 90 %
For more information, please visit the product page | For information on related products, view Dc Power Jacks