Table 3
TEST PROCEDURES AND REQUIREMENTS
TEST
PROCEDURE
(quick reference)
REQUIREMENTS
NAME OF TEST REFERENCE
Endurance
IEC 60384-4/
EN130300
subclause 4.13
T
amb
= 125 °C;
U
R
= 6.3 V to 25 V with U
R
applied;
U
R
= 40 V with U
C
applied;
10 000 h
C/C: ± 10 %
tan 1.2 x spec. limit
Z 1.2 x spec. limit
I
L5
spec. limit
Useful life
CECC 30302
subclause 1.8.1
T
amb
= 125 °C;
I
R
applied and:
U
R
= 6.3 V to 25 V with U
R
applied;
U
R
= 40 V with U
C
applied;
20 000 h
C/C: ± 15 %
tan 1.5 x spec. limit
Z 1.5 x spec. limit
I
L5
spec. limit
no short or open circuit,
no visible damage
total failure percentage: < 1 %
Shelf life (storage at
high temperature)
IEC 60 384-4/
EN130 300
subclause 4.17
T
amb
= 125 °C; no voltage applied;
500 h
C/C: ± 10 %
tan 1.2 x spec. limit
I
L5
spec. limit
Charge and discharge
IEC 60384-4-2
subclause 9.21
10
6
cycles without series resistance:
0.5 s to U
R
;
0.5 s to ground
C/C: ± 5 %
no short or open circuit,
no visible damage
Solvent resistance
IEC 60068-2-45,
test XA
IEC 60653
Immersion: 5 min ± 0.5 min with or without
ultrasonic at 55 °C ± 5 °C
Solvents: demineralized water and/or calgonite
solution (20 g/l)
Visual appearance not affected
Extended vibration
IEC 60068-2-6
test Fc
10 Hz to 2000 Hz; 1.5 mm or 20 g;
1 octave/min; 3 directions;
1 sweep per direction; no voltage applied
no intermittent contacts
no breakdown
no open circuiting
no mechanical damage
C/C: ± 5 %
tan 1.2 x spec. limit
Z 1.2 x spec. limit
I
L5
1.5 x spec. limit
Shock
IEC 60068-2-27
test Ea
Half-sine or sawtooth pulse shape; 50 g; 11 ms;
3 successive shocks in each direction of
3 mutually perpendicular axes;
no voltage applied
no intermittent contacts
no breakdown
no open circuiting
no mechanical damage
C/C: ± 5 %
tan 1.2 x spec. limit
Z 1.2 x spec. limit
I
L5
1.5 x spec. limit
Passive flammability IEC 60695-2-2
Capacitor mounted to a vertical printed-circuit
board, one flame on capacitor body;
T
amb
= 20 °C to 25 °C;
test duration = 20 s
After removing the test flame from
the capacitor, the capacitor must
not continue to burn for more than
15 s; no burning particles must drop