OMH3075S

© TT electronics plc
General Note
TT Electronics reserves the right to make changes in product specification without
notice or liability. All information is subject to TT Electronics’ own data and is
considered accurate at time of going to print.
Issue K-1 08/2016 Page 4
OPTEK Technology, Inc.
1645 Wallace Drive, Carrollton, TX 75006|Ph: +1 972 323 2200
www.optekinc.com | www.ttelectronics.com
High Reliability Hallogic® Hall-
Effect Sensors
OMH090, OMH3019, OMH3020, OMH3040,
OMH3075, OMH3131 (B, S versions)
Electrical Characteristics (V
CC
= 4.5 V to 24 V, T
A
= 25° C unless otherwise noted)
OMH3020, OMH3020B, OMH3020S Uni-Polar
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
B
OP
Magnetic Operate Point
(1)
70
-
220
-
350
425
Gauss
+25°C
-55°C & +125°C
B
RP
Magnetic Release Point
50
25
180
-
330
-
Gauss
+25°C
-55°C & +125°C
B
H
Magnetic Hysteresis
15
10
55
-
200
-
Gauss
+25°C
-55°C & +125°C
Icc Supply Current - 4 7 mA V
CC
= 24 V, Output On, B ≤ 50 Gauss
V
OL
Output Saturation Voltage - 100 400 mV V
CC
= 4.5 V, I
OL
= 15 mA, B ≥ 350 Gauss
I
OH
Output Leakage Current - 0.10 10 μA V
CC
= 24 V, V
OUT
= 24 V, B ≤ 50 Gauss
t
r
Output Rise Time - 0.21 1 μs
t
f
Output Fall Time - 0.10 1 μs
R
L
= 820 Ω, C
L
= 20 pF, V
CC
= 12 V
(guaranteed not tested)
Notes:
(1) South pole facing symbolized surface.
Electrical Characteristics (V
CC
= 4.5 V to 24 V, T
A
= 25° C unless otherwise noted)
OMH3040, OMH3040B, OMH3040S Uni-Polar
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
B
OP
Magnetic Operate Point
(1)
70
75
150
-
200
270
Gauss
+25°C
-55°C & +125°C
B
RP
Magnetic Release Point
50
25
115
-
180
210
Gauss
+25°C
-55°C & +125°C
B
H
Magnetic Hysteresis
10
20
35
-
60
-
Gauss
+25°C
-55°C & +125°C
Icc Supply Current
-
-
4
-
8
8
10
mA
+25°C, V
CC
= 24 V, Output On, B ≥ 300 Gauss
+125°C
-55°C
V
OL
Output Saturation Voltage - 100 400 mV V
CC
= 4.5 V, I
OL
= 20 mA, B ≥ 250 Gauss
I
OH
Output Leakage Current
-
-
-
-
0.10
-
11
10
12
μA
-55°C, V
CC
= 24V, V
OUT
= 24V, B ≤ 75 Gauss
+25°C, V
CC
= 24V, V
OUT
= 24V, B ≤ 100 Gauss
+125°C ,V
CC
= 24V, V
OUT
= 24V, B ≤ 75 G
t
r
Output Rise Time - 0.21 1 μs
t
f
Output Fall Time - 0.10 1 μs
R
L
= 820 Ω, C
L
= 20 pF, V
CC
= 12 V
(guaranteed not tested)
© TT electronics plc
General Note
TT Electronics reserves the right to make changes in product specification without
notice or liability. All information is subject to TT Electronics’ own data and is
considered accurate at time of going to print.
Issue K-1 08/2016 Page 5
OPTEK Technology, Inc.
1645 Wallace Drive, Carrollton, TX 75006|Ph: +1 972 323 2200
www.optekinc.com | www.ttelectronics.com
High Reliability Hallogic® Hall-
Effect Sensors
OMH090, OMH3019, OMH3020, OMH3040,
OMH3075, OMH3131 (B, S versions)
Electrical Characteristics (V
CC
= 4.5 V to 24 V, T
A
= 25° C unless otherwise noted)
OMH3075, OMH3075B, OMH3075S Bi-Polar Latching
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
B
OP
Magnetic Operate Point
(1)
50
25
150
-
250
275
Gauss
+25°C
-55°C & +125°C
B
RP
Magnetic Release Point
-250
-275
-150
-
-50
-25
Gauss
+25°C
-55°C & +125°C
B
H
Magnetic Hysteresis
100
50
250
-
500
-
Gauss
+25°C
-55°C & +125°C
I
CC
Supply Current
-
-
4
-
8
8
10
mA
+25°C, V
CC
= 24 V, (Output On), B -250 Gauss
+125°C
-55°C
V
OL
Output Saturation Voltage
-
-
-
-
100
-
500
400
400
mV
-55°C
+25°C, V
CC
= 4.5 V, I
OL
= 20 mA, B ≥ 250 Gauss
+125°C
I
OH
Output Leakage Current - 0.10 1.0 μA V
CC
= 24 V, V
OUT
= 24 V, B ≤ -250 Gauss
t
r
Output Rise Time - 0.21 1 μs
t
f
Output Fall Time - 0.10 1 μs
R
L
= 820 Ω, C
L
= 20 pF, V
cc
= 12 V
(guaranteed not tested)
Notes:
(1) South pole facing symbolized surface.
Electrical Characteristics (V
CC
= 4.5 V to 24 V, T
A
= 25° C unless otherwise noted)
OMH3131, OMH3131B & OMH3131S Uni-Polar
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
B
OP
Magnetic Operate Point
(1)
20
10
60
-
95
150
Gauss
+25°C
-55°C to +125°C
B
RP
Magnetic Release Point
10
5
45
-
85
145
Gauss
+25°C
-55°C to +125°C
B
H
Magnetic Hysteresis
5
5
15
-
40
145
Gauss
+25°C
-55°C to +125°C
I
CC
Supply Current - 4 7 mA V
CC
= 24 V, Output On, B > 250 Gauss
V
OL
Output Saturation Voltage - 100 400 mV V
CC
= 4.5 V, I
OL
= 15 mA, B ≥ 250 Gauss
I
OH
Output Leakage Current - 0.10 10 μA V
CC
= 24 V, V
OUT
= 24 V, B ≤ 0 Gauss
t
r
Output Rise Time - 0.21 1 μs
t
f
Output Fall Time - 0.10 1 μs
R
L
= 820 Ω, C
L
= 20 pF, V
cc
= 12 V
(guaranteed not tested)
© TT electronics plc
General Note
TT Electronics reserves the right to make changes in product specification without
notice or liability. All information is subject to TT Electronics’ own data and is
considered accurate at time of going to print.
Issue K-1 08/2016 Page 6
OPTEK Technology, Inc.
1645 Wallace Drive, Carrollton, TX 75006|Ph: +1 972 323 2200
www.optekinc.com | www.ttelectronics.com
High Reliability Hallogic® Hall-
Effect Sensors
OMH090, OMH3019, OMH3020, OMH3040,
OMH3075, OMH3131 (B, S versions)
OMH090, OMH3019, OMH3020, OMH3040, OMH3075, OMH3131 (B, S)
Magnetic Operate & Release Points vs Temperature
0
20
40
60
80
100
120
140
160
180
-60 -40 -20 0 20 40 60 80 100 120 140 160
Temperature (°C)
Manetic Flux Level - Gauss
OMH090 Release
OMH090 Operate
OMH3131 Release
OMH3131 Operate
OMH3040 Release
OMH3040 Operate
Magnetic Operate & Release Points vs Temperature
-200
-100
0
100
200
300
400
-60 -40 -20 0 20 40 60 80 100 120 140 160
Temperature (°C)
Manetic Flux Level - Gauss
OMH3075 Release
OMH3075 Operate
OMH3019
OMH3019 Operate
OMH3020 Release
OMH3020 Operate

OMH3075S

Mfr. #:
Manufacturer:
Description:
Magnetic Sensors Board Mount Hall Effect / Magnetic Sensors Hall Effect Senso
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union