MPXV4006G
Sensors
4 Freescale Semiconductor
PRESSURE (P1)/VACUUM (P2) SIDE IDENTIFICATION TABLE
Freescale designates the two sides of the pressure sensor
as the Pressure (P1) side and the Vacuum (P2) side. The
Pressure (P1) side is the side containing silicone gel which
isolates the die from the environment. The pressure sensor is
designed to operate with positive differential pressure
applied, P1 > P2.
The Pressure (P1) side may be identified by using the
table below:
MINIMUM RECOMMENDED FOOTPRINT FOR SURFACE MOUNTED APPLICATIONS
Surface mount board layout is a critical portion of the total
design. The footprint for the surface mount packages must be
the correct size to ensure proper solder connection interface
between the board and the package. With the correct
footprint, the packages will self align when subjected to a
solder reflow process. It is always recommended to design
boards with a solder mask layer to avoid bridging and
shorting between solder pads.
Figure 5. SOP Footprint (Case 482)
Table 3. Pressure (P1)/Vacuum (P2) Side Identification Table
Part Number Case Type Pressure (P1) Side Identifier
MPXV4006G6U/T1 482 Stainless Steel Cap
MPXV4006GC6U/T1 482A Side with Port Attached
MPXV4006G7U 482B Stainless Steel Cap
MPXV4006GC7U 482C Side with Port Attached
MPXV4006GP 1369 Side with Port Attached
MPXV4006DP 1351 Side with Part Marking
0.660
16.76
0.060 TYP 8X
1.52
0.100 TYP 8X
2.54
0.100 TYP
2.54
0.300
7.62
inch
mm