Connectors for industrial equipment
AXW
SPECIFICATIONS
1. Characteristics
2. Materials and surface treatment
3. Applicable cable
DIMENSIONS (Unit: mm)
Item Specifications Conditions
Electrical
characteristics
Rated current AWG#22, 24: 3A, AWG#26: 2A, AWG#28: 1A
Rated voltage 250V AC
Breakdown voltage 1,000V AC for 1 min. Detection current: 1mA
Insulation resistance Min. 1,000M Using 500V DC megger
Contact resistance Max. 20m
Measured based on the HP4338B measurement method of
JIS C 5402
Mechanical
characteristics
Unit removal force Min. 0.343N {35gf}
Measured by steel-pin-gauge with 0.64±0.01mm square
(surface roughness 0.1µm)
Composite insertion force Max. 2.94N {300gf} × No. of contacts
Life time
characteristics
Insertion and removal life 500 times Repeat insertion and removal speed of max. 600 times/hour
Environmental
characteristics
Ambient temperature –50°C to 105°C
No freezing at low temperatures
Ambient temperature of cables should be considered
Vibration resistance
Double amplitude: 1.52mm
Frequency: 10 to 55Hz (for 3 axes)
No interruption of current longer than 1µs
(Max. carrying current 100mA should be impressed during
the test)
Shock resistance 490m/s
2
{50G} (for 3 axes)
No interruption of current longer than 1µs
(Max. carrying current 100mA should be impressed during
the test)
Part name Materials Surface treatment
Housing Glass fiber reinforced PBT (UL94V-0)
Cover
Semi-cover Glass fiber reinforced PBT (UL94V-0)
Hood cover
Glass fiber polycarbonate resin (UL94V-0)
Ver tical type hood cover (16, 20 contact)
Contact Copper alloy
Contact portion:
Ni plating on base, Au plating on surface
Contact pressure portion:
Ni plating on base, Sn plating on surface
Lead wire bundling metal
(enclosed with vertical type hood cover)
Steel plate
Lead wire bundling band
(enclosed with angled type hood cover)
Polyimide resin
No. Cross section area External figure Rated current Remarks
AWG#22 0.3 mm
2
1.5 to 1.1 dia.
3A 12 wires/0.18 should used
AWG#24 0.2 mm
2
3A
AWG#26 0.14mm
2
1.3 to 1.1 dia.
2A
AWG#28 0.08mm
2
1A
The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac
• Housing with contacts
Dimension table (mm)
No. of
contacts
Polarity
guide
A B
10 0 17.3 10.16
10 1 17.3 10.16
14 1 22.4 15.24
16 1 24.9 17.78
20 1 30.0 22.86
26 1 37.6 30.48
30 1 42.7 35.56
34 1 47.8 40.64
40 1 55.4 48.26
50 1 68.1 60.96
60 1 80.8 73.66
64 1 85.9 78.74
General tolerance: ±0.3
14.5±0.2
14.2
6.0±0.2
A
B±0.2
2.54±0.1
2.54±0.1
Note) Dimensions of the housing without contact is the same as the right figure.
CAD Data
panasonic-electric-works.net/ac
Discontinued as of September 30, 2010
Connectors for industrial equipment
AXW
• Socket
1) When vertical type hood covers are mated (16, 20, 26, 30, 34, 40, 50, 60 and 64 contacts)
Dimension table (mm)
No. of
contacts
A B C D
16 24.0 24.92 17.78 33.5
20 27.8 30.0 22.86 33.5
26 28.5 37.6 30.48 33.5
30 33.5 42.7 35.56 33.5
34 38.6 47.8 40.64 33.5
40 43.6 55.4 48.26 41.5
50 56.0 68.1 60.96 41.5
60 68.7 80.8 73.66 41.5
64 73.8 85.9 78.74 41.5
16 and 20 contacts
A
M2.6 screw
Wire bunding metal
B
D
C±0.2
14.5±0.2
6.0±0.2
14.2
22.7
7.5
8.0
9.6
2.54±0.1
2.54±0.1
26 to 64 contacts
General tolerance: ±0.3
Screw
Cover
A
Wire bunding metal
B
D
C±0.2
14.4±0.2
6.0±0.2
14.2
20.6
7.5
8.0
12.0
2.54±0.1
2.54±0.1
Nut
CAD Data
2) When angle type hood covers are mated (26, 30, 34, 40, 50, 60 and 64 contacts)
Dimension table (mm)
No. of
contacts
A B C D
26 40.5 37.5 30.48 41.5
30 45.6 42.6 35.56 41.5
34 50.7 47.7 40.64 41.5
40 62.5 55.3 48.26 52.5
50 75.2 68.0 60.96 52.5
60 87.9 80.7 73.66 52.5
64 93.0 85.8 78.74 52.5
General tolerance: ±0.3
A
B
D
C±0.2
14.5±0.2
6.0±0.2
14.2
22.7
7.5
8.0
12.0
2.54±0.1
2.54±0.1
CAD Data
3) When semi-covers are mated
Dimension table (mm)
No. of
contacts
A B
10 17.3 10.16
14 22.38 15.24
16 24.92 17.78
20 30.0 22.86
26 37.62 30.48
30 42.7 35.56
34 47.78 40.64
40 55.4 48.26
50 68.1 60.96
60 80.8 73.66
64 85.88 78.74
General tolerance: ±0.3
A
B±0.2
14.5±0.2
6.0±0.2
14.2
16.5
7.5
8.0
2.54±0.1
2.54±0.1
CAD Data
panasonic-electric-works.net/ac
Discontinued as of September 30, 2010
Connectors for industrial equipment
AXW
NOTES
4) Contacts (5 in line)
Note) On the contacts there are
stamps “22” for AWG #22
and #24 types, and “26” for
AWG #26 and #28 types.
General tolerance: ±0.3
CAD Data
1. Use wires and contact types that
match.
The contact’s clamp is tamped with 22 or
26.
Use AWG#22 or #24 wire with the type
22 contact and AWG #26 or #28 wire with
the type 26 contact.
An incorrect combination will cause faulty
connections.
2. Use wires having a correct outer
insulation diameter.
The use of a wire with an outer insulation
diameter larger than the allowable value
or a wire with a hard material for the
insulation will cause faulty connections.
Furthermore, the use of a wire with an
outer insulation diameter less than the
allowable value will cause a drop in the
clamp strength. Use wires with a suitable
outer diameter and insulation material.
Suitable wire diameters are shown in the
table below.
Suitable wire diameters
*AWG#22 and #24 use different contacts from
AWG#26 and #28. Refer to the part number chart for
the part number.
3. Inserted wire length during wire
pressure welding
Insert the wire to a proper length and
perform the pressure welding.
If the inserted length is too short, the wire
will be pressure welded only at one
location.
If the inserted length is too long, the wire
will end up on the lance portion and a
proper pressure welding will not be
obtained.
4. Cut the end of the wire so that it is
straight and flat. Be sure no uneven
strands remain.
5. When pressure welding a wire, fully
insert it to the proper position. Be sure
to squeeze the lever unit it reaches the
end position of the stroke.
6. After connecting the wire, check
that the wire clamp firmly clamps the
wire.
7. It may not be possible to cut a
contact from the carrier by folding the
contact only once.
8. The contact holder should be
replaced as needed.
Size
Insulation
outer
diameter
Remark
AWG#22
1.5 dia. to
1.1 dia.
AWG #22 is Stranded
wire of 12 stands/0.18
AWG#24 Stranded wire
AWG#26
1.3 dia. to
1.1 dia.
Stranded wire
AWG#28
For other details, please verify with
the product specification sheets.
panasonic-electric-works.net/ac
Discontinued as of September 30, 2010

AXW7221

Mfr. #:
Manufacturer:
Panasonic
Description:
Headers & Wire Housings Contact-sets for AXW Wire Press Socket(f
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet