cui.com
CUI Inc │ SERIES: VYC30W │ DESCRIPTION: DC-DC CONVERTER date 08/29/2012 │ page 2 of 6
INPUT
parameter conditions/description min typ max units
operating input voltage
9
18
24
48
36
75
Vdc
Vdc
start-up time 10 ms
under voltage lockout
power up 24 V input
power up 48 V input
power down 24 V input
power down 48 V input
8.0
16.0
9.0
17.8
Vdc
Vdc
Vdc
Vdc
Remote on/off
1
module off
module on (or open circuit)
0
3.5
1.2
12
Vdc
Vdc
fi lter PI type
Notes: 1. The on/off pin voltage is referenced to GND
OUTPUT
parameter conditions/description min typ max units
line regulation
single and dual output models, measured from
low line to high line at full load
triple output models (main output), measured
from low line to high line at full load
triple output models (auxiliary outputs), measured
from low line to high line at full load
±0.2 ±0.5
±1
±5
%
%
%
load regulation
single and dual output models, measured from
10% to full load at nominal input
triple output models (main output), measured
10% to full load at nominal input
triple output models (auxiliary outputs), measured
10% to full load at nominal input
±0.5 ±1
±2
±5
%
%
%
voltage accuracy
single and dual output models, refer to
recommended circuit
triple output models (main output), refer to
recommended circuit
triple output models (auxiliary outputs), refer to
recommended circuit
±1
±2
±5
±3 %
%
%
transient recovery time 25% ~ 50% ~ 25% step load charge 300 500 s
transient peak deviation 25% rated load change 300 s
cross regulation
dual output models, main output 50% load,
supplemental output from 10~100% load
triple output models, main output and one
auxiliary output 50% load, another auxiliary
output from 10~100% load
±5 %
adjustability ±10% Vdc
switching frequency 100% load, input voltage range 400 kHz
temperature coeffi cient ±0.02 %/°C
PART NUMBER KEY
VYC30W - QXX - X XX - X
Input Voltage Output Voltage
Base Number
Heatsink
"blank" = No
H = Yes
Output
S = single output
D = dual output
T = triple output
For more information, please visit the product page.