SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY(Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
Note.5
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
±3.0%
±10%
±10%
90 ~ 277VAC 127~392VDC
47 ~ 63Hz
0.4A/115VAC 0.2A/230VAC 0.15A/277VAC
COLD START 25A(twidth=60 s measured at 50% Ipeak) at 230VACμ
0.5mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms/500VDC / 25 / 70%RH℃
-30 ~ +60 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.06%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
20W Single Output LED Power Supply
■ Features :
PLP-20 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
CONSTANT CURRENT REGION
Note.5
CURRENT ADJ. RANGE
75% ~ 100%
Universal AC input / Full range(up to 277VAC)
Protections:Short circuit/Over current/Over voltage/Over temperature
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Built-in active PFC function
ⅡClass power unit, no FG
Class 2 power unit
Small and compact size
100% full load burn-in test
High reliability,low cost
Suitable for built-in applications of LED lighting
2 years warranty
Shut down o/p voltage, recovers automatically after temperature goes down
TUV EN61347-1, EN61347-2-13, GB19510.14 GB19510.1 UL8750, CSA C22.2 No. 250.0-08,EAC TP TC 004 approved,,
File Name:PLP-20-SPEC 2018-01-11
140*32*22(L*W*H)
0.12kg;60pcs/9.2kg/0.62CUFT
500ms / 230VAC 2000ms / 115VAC at full load
PLP-20-18
PLP-20-24
PLP-20-36
18V
13.5 ~ 18V
24V
18 ~ 24V
36V
1.1A
0.8A
0.55A
0 ~ 1.1A
0 ~ 0.8A
0 ~ 0.55A
19.8W
19.2W
19.8W
3.0Vp-p
3.0Vp-p
3.0Vp-p
PLP-20-48
48V
0.42A
0 ~ 0.42A
20.2W
3.8Vp-p
36 ~ 48V
27 ~ 36V
PLP-20-12
12V
9 ~ 12V
1.6A
0 ~ 1.6A
19.2W
2.5Vp-p
81%
82%
83%
83.5%
80%
19 ~ 22V
27 ~ 34V
41 ~ 46V
54 ~ 60V
14 ~ 16V
Protection type : Shut off o/p voltage, clamping by zener diode
VOLTAGE RANGE
Note.4
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage, please check the static characteristic for more details.
5. lease refer to "DRIVING METHODS OF LED MODULE".
P
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
643.6Khrs min. MIL-HDBK-217F (25 )℃
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C( 75% load); EN61000-3-3,EAC TP TC 020≧
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level, criteria A,EAC TP TC 020
EMC IMMUNITY
EMC EMISSION
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
92 units (circuit breaker of type B) / 98 units (circuit breaker of type C) at 230VAC
THD< 20% when output loading 75% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧