V. Quality Assurance Information
A. Quality Assurance Contacts: Ken Wendel (Director, Reliability Engineering)
Bryan Preeshl (Managing Director of QA)
B. Outgoing Inspection Level: 0.1% for all electrical parameters guaranteed by the Datasheet.
0.1% For all Visual Defects.
C. Observed Outgoing Defect Rate: < 50 ppm
D. Sampling Plan: Mil-Std-105D
VI. Reliability Evaluation
A. Accelerated Life Test
MAX3986UTU+
The results of the 135°C biased (static) life test are shown in Table 1. Using these results, the Failure Rate ( ) is calculated as
follows:
= 1 = 1.83 (Chi square value for MTTF upper limit)
MTTF 192 x 4340 x 50 x 2
(where 4340 = Temperature Acceleration factor assuming an activation energy of 0.8eV)
= 21.5 x 10
-9
= 21.5 F.I.T. (60% confidence level @ 25°C)
The following failure rate represents data collected from Maxim’s reliability monitor program. Maxim performs quarterly 1000
hour life test monitors on its processes. This data is published in the Product Reliability Report found at http://www.maxim-ic.com/.
Current monitor data for the MB3H Process results in a FIT Rate of 1.84 @ 25C and 22.3 @ 55C (0.8 eV, 60% UCL)
B. Moisture Resistance Tests
The industry standard 85°C/85%RH or HAST testing is monitored per device process once a quarter.
C. E.S.D. and Latch-Up Testing
The HQ23 die type has been found to have all pins able to withstand a HBM transient pulse of +/-2000 V per JEDEC
JESD22-A114. Latch-Up testing has shown that this device withstands a current of +/-250 mA, 1.5x VCCMax Overvoltage per
JESD78.