G32A-C
2
Application Examples
• The G32A-C can be used to prevent malfunction due to residual
voltage, leakage current, and input noise.
Residual Voltage
In rated operation, the G3PA turns ON at 4 V max. Ordinarily, the
G3PA might turn ON if the residual voltage in transistor circuits
exceeds 3 V. (The G32A-C makes voltage output at voltages
exceeding 9.6 V.)
• The G32A-C can be used to improve the synchronization of input
signals during 3-phase load switching.
• The G32A-C can be used to fix the trigger voltage when using a
timing circuit.
Specifications
■ Ratings (at an Ambient Temperature of 25°C)
■ Characteristics
G32A-C
G3PA
Residual voltage
Item Specifications
Rated input voltage 12/24 VDC
Rated input current One G3PA 8 mA max. (when 24 VDC applied)
Two G3PAs 14 mA max. (when 24 VDC applied)
Must operate voltage 9.6 V ±10%
Must release voltage 5 V min.
Output voltage 12 VDC ±15%
Item Specifications
Input voltage range 10.2 to 30 VDC
Operate time 1 ms max.
Release time 1 ms max.
Vibration resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (when mounted using screws)
Shock resistance
300 m/s
2
(approx. 30 G)
Ambient temperature Storage: –30 to 100°C (with no icing or condensation)
Operating: –30 to 80°C (with no icing or condensation)
Ambient operating humidity 45% to 85%
Weight Approx. 65 g