G-NIMO-005

TSYS02D Digital Temperature Sensor
TSYS02D Rev 3 www.meas-spec.com 2013-03
4/8
CONNECTION DIAGRAM
PIN FUNCTION TABLE
Pin
Name
Type
Function
1
VDD
Power
Supply Voltage
2
SCL
Digital Input
I
2
C: Serial Data Clock
3
SDA
Digital Input/Output
I
2
C Data Input / Output
4
VSS
Power
Ground
5 8
NC
---
Not connected / Do not connect
INTERFACE DESCRIPTION
I
2
C INTERFACE
An I
2
C communication message starts with a start condition and it is ended by a stop condition.
Each command consists of two bytes: the address byte and command byte.
I
2
C ADDRESS
The I
2
C address is 0b1000000x.
COMMANDS
There are four commands:
Reset
Read PROM (serial number)
Read ADC16 Temperature Data (with SCL hold)
Read ADC16 Temperature Data (without SCL hold)
Command
Hex Value
Reset
0x7E
Read ADC16 Temperature Data (with SCL hold)
0x E3
Read ADC16 Temperature Data (without SCL hold)
0x F3
Read first 8 bytes of Serial Number
0x FA0F
Read last 6 bytes of Serial Number
0x FCC9
TSYS02D
VDD
+3.3V
VDD
+3.3V
TSYS02D Digital Temperature Sensor
TSYS02D Rev 3 www.meas-spec.com 2013-03
5/8
RESET SEQUENCE
The reset of TSYS02D can be sent at any time. When SDA line is blocked by an undefined state the
only way to get the TSYS02D to work is to send a power on reset or several SCL cycles. This is not
needed when the last command was not a conversion.
CONVERSION AND ADC READ
A conversion can be started by sending this command to TSYS02D. When the command is sent to the
sensor it stays busy until conversion is done. All other commands except the reset command will not be
executed during this time. When conversion is finished the data can be accessed by sending a Read
command. If an acknowledge appears from the TSYS02D, you may then send 24 SCLK cycles to get all
result bits. Every 9
th
bit the system waits for acknowledge. If the acknowledge is not sent the data
clocking out of the chip stops. Two types of conversion commands for temperature reading are possible.
If the “hold” command is issued, the SCL is held low during conversion, indicating when the conversion
is finished. If the “no hold” is issued, the SCL line is not controlled by the TSYS02D.
WITH HOLD
WITHOUT HOLD
TSYS02D Digital Temperature Sensor
TSYS02D Rev 3 www.meas-spec.com 2013-03
6/8
READ SERIAL NUMBER FIRST 8 BYTES
READ SERIAL NUMBER LAST 6 BYTES
TEMPERATURE CALCULATION
TEMPERATURE POLYNOMAL
ADC16: ADC Result 16 bits
T / °C = ADC16 / 2
16
x 175.72 46.85
EXAMPLE
ADC16: 36636
T / °C = 36636 / 2
16
x 175.72 46.85
T / °C = 51.38°C