TMV 2HI Series, 2 Watt
http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current no load 5 Vin models: 35 mA typ.
12 Vin models: 17 mA typ.
15 Vin models: 16 mA typ.
24 Vin models: 12 mA typ.
Surge voltage (1 sec. max.) 5 Vin models: 9 V max.
12 Vin models: 18 V max.
15 Vin models: 20 V max.
24 Vin models: 30 V max.
Input filter internal capacitor
Output Specifications
Voltage set accuracy ±5 % max.
Voltage balance (dual output models, balanced loads) 0.1 % typ. / 1 % max.
Regulation – Input variation (1 % change of Vin) 1.2 % typ.
– Load variation (20 – 100 %) 3.3 Vout models: < 20 %
(±)5 Vout models: < 15 %
other models: < 10 %
Ripple and noise (20 MHz Bandwidth) 100 mVp-p max.
Short circuit protection continuous, automatic recovery
Temperature coefficient ±0.01 %/K typ. / ±0.02 %/K max.
Capacitive load –Single output 3.3 Vout models: 1650 µF max.
5.0 & 9.0 Vout models: 940 µF max.
12 & 15 Vout models: 440 µF max.
–Dual output ±5.0 & ±9.0 Vout models: 440 µF max. (each output)
±12 & ±15 Vout models: 200 µF max. (each output)
+15 / –9 Vout models: 200 / 440 µF max.
Isolation /Safety
Isolation voltage – Isolation test voltage (tested for 1 s) 5‘700 Vpk
– I/O isolation voltage (60 s) 5’200 VDC
Isolation capacitance (input/output) 7 pF typ.
Isolation resistance (input/output) >10 Gohm
Common mode transient immunity (dv/dt) 15 kV/µs min.
General Specifications
Temperature ranges – Operating –40°C to +85°C
– Case temperature +95°C max.
– Storage temperature –55°C to +125°C
Derating 6.7 %/K above +80°C
Humidity (non condensing) 95 % rel H max.
Altitude during operation 4000 m
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign) >1‘109‘000 h
Switching frequency 100 kHz typ.
Safety standards CAN/CSA-C22.2 No 60950-1-07, 2nd ed; A1:2011
ANSI/UL No. 60950-1, 2nd ed.; A1:2011
IEC 60950-1:2005 (2nd edition); Am 1:2009
EN 60950-1:2006/A11:2009/A1:2010/A12:2011
– Certification documents www.tracopower.com/overview/tmv2hi
Environmental compliance – Reach www.tracopower.com/products/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU