MC74HC4067A
www.onsemi.com
3
MAXIMUM RATINGS
Symbol Parameter Value Unit
V
CC
DC Supply Voltage −0.5 to +7.0 V
V
IS
Analog Input Voltage −0.5 to V
CC
+
0.5 V
V
IN
Digital Input Voltage −0.5 to V
CC
+
0.5 V
I
IK
Input Clamping Current V
IN
< −0.5 V or V
IN
> V
CC
+
0.5 V ±20 mA
I
SK
Switch Input Clamping Current V
IS
< −0.5 V or V
IS
> V
CC
+
0.5 V ±20 mA
I
IS
DC Switch Current ±25 mA
I
O
DC Output Source / Sink Current ±25 mA
I
CC
DC Supply Current per Supply Pin ±100 mA
I
GND
DC Ground Current per Ground Pin ±100 mA
T
STG
Storage Temperature Range −65 to +150
_C
T
L
Lead Temperature, 1 mm from Case for 10 Seconds 260
_C
T
J
Junction Temperature under Bias +150
_C
q
JA
Thermal Resistance SOIC
TSSOP
97
148
_C/W
P
D
Power Dissipation in Still Air at 85_C SOIC
TSSOP
500
450
mW
MSL Moisture Sensitivity Level 1
F
R
Flammability Rating Oxygen Index: 30% − 35% UL−94−VO (0.125 in)
V
ESD
ESD Withstand Voltage Human Body Model (Note 1)
Machine Model (Note 2)
>3000
>200
V
I
Latchup
Latchup Performance Above V
CC
and Below GND at 85_C (Note 3)
±100 mA
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. Tested to EIA/JESD22−A114−A.
2. Tested to EIA/JESD22−A115−A.
3. Tested to EIA/JESD78.
RECOMMENDED OPERATING CONDITIONS
Symbol Parameter Min Max Unit
V
CC
Positive DC Supply Voltage (Referenced to GND) 2.0 6.0 V
V
IS
Analog Input Voltage (Referenced to GND) GND V
CC
V
V
in
Digital Input Voltage (Referenced to GND) GND V
CC
V
V
IO
* Static or Dynamic Voltage Across Switch − 1.2 V
T
A
Operating Temperature, All Package Types –55 +125 °C
t
r
, t
f
Input Rise and Fall Rate (Digital Inputs) V
CC
= 2.0 V
V
CC
= 3.0 V
V
CC
= 4.5 V
V
CC
= 6.0 V
0
0
0
0
1000
600
500
400
ns
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond
the Recommended Operating Ranges limits may affect device reliability.
*For voltage drops across the switch greater than 1.2 V (switch on), excessive V
CC
current may be drawn; i.e., the current out of the switch may
contain both V
CC
and switch input components. The reliability of the device will be unaffected unless the Maximum Ratings are exceeded.