PDA040W Characteristics
WWW.PHIHONG.COM
INPUT:
AC Input Voltage Rating
100VAC to 277VAC
AC Input Frequency
47~63Hz
Maximum Input Current
≤ 0.8A
Leakage Current
0.25mA maximum
Power Factor
≥ 0.9
THD
< 20%
OUTPUT:
Output Current Ripple
<40%
Efficiency
Auxiliary Power Supply
12V semi regulated (11-14Vdc)
0-10mA
Voltage Dimming Function:
0-10VDC
Resistive Dimming*
Resistor must be placed between Dim+ and Dim- for operation.
See following page for dimming table.
Environmental:
Temperature
Operation case +75°C
Non-operation -40 to +80°C
Operating Humidity 20 to 95%
*Output derates from 50°C to 62°C Ta
EMC
FCC 47 Part 15 Class B, EN55015 Class B
Immunity
IEC61000-4-2
IEC61000-4-4
IEC61000-4-5
IEC61000-4-11
Dielectric Withstand (Hi-pot) Test
Primary to secondary: 3000VAC for 1 minute, 10mA
Insulation Resistance
Primary to secondary: >10M Ohm 500VDC, 1 Minute
FEATURES:
Short-Circuit Protection
The PSU will withstand a short circuit across the
outputs without damage
Input Over Current Protection
The input power line will be fused with a 2A/300V fuse
Output Over-voltage Protection
Auto shutdown
Input / Output Connections
Position
Specification Length
Input
Black AWG16 Solid Wire 350mm
Output
Warranty
5 Years