DRAWING NUMBER REV.
FPSC 5001U 3
Millimeters
2 Place Dec.
1 Place Dec.
When Unspecified
Scale :
Inches
2 Place Dec.
3 Place Dec.
Fractions
-
+
-
+
+
-
Angles
TOLERANCES
DRAWING NUMBER
Dwn.
App'd.
TITLE
-
+
-
+
+
-
Standex
Electronics
a
Standex
company
DATE
CINCINNATI
OHIO
REV.
This drawing and the information and technical data contained hereon,
are confidential and proprietary to Standex Electronics and shall
not be used in whole or in part without Standex written consent
FPSC 5001U
4/2/2012CCR
N/A
3
X/X
.XXX
.XX .X
.XX
X°
4/3/2012DCJ
FPS-T
REVISIONS
1
INITIAL RELEASE
4/3/12 DCJ
2
ADD
INSTALLATION
INSTRUCTIONS;
ADD WATER
LEVEL; ADD
DIMENSIONS
10/25/12 DCJ
3
ADD CUSTOM
TEE FITTINGS;
3/4" PLUG WAS 1"
PLUG; REMOVE
BUSHING; ADD
MARKING VIEWS
1/7/13 DCJ
NOTES:
1. FLOAT MATERIAL: POLYPROPYLENE, WHITE
2. HOUSING AND RETAINER RING MATERIAL: POLYPROPYLENE, BLACK
3. O-RING MATERIAL: SILICONE
4. OPERATING TEMPERATURES UP TO 70°C
5. STORAGE TEMPERATURE UP TO 105°C
6. ELECTRICAL CHARACTERISTICS:
- POWER RATING (MAX) 50VA
- SWITCHING VOLTAGE (MAX) 200 VDC, 150 VAC
- BREAKDOWN VOLTAGE (MIN) 250VDC
- CONTACT ARRANGEMENT SPST
- SWICHING CURRENT (MAX) 1.5 A DC, 1.5 A AC
- CARRY CURRENT (MAX) 2.5 A DC, 2.5 A AC
- CONTACT RESISTANCE 100 m
- INSULATION RESISTANCE (MIN) 10¹²
- SWITCH AGENCY LISTED UL E122752
7. WIRE CONNECTIONS: 18AWG UL1007/1569 OR UL2468
8. FLOAT SPECIFIC GRAVITY: 0.75 (REFERENCE ONLY)
9. PLASTIC MATERIAL REGULATORY COMPLIANCE: FDA, RoHS, UL
10. CONFORMS TO UL508
11. MUST PASS MINIMUM OF 30 LBS. WIRE PULL TEST USING DEAD
WEIGHT FOR ONE MINUTE
BOM FOR PACKAGE
ITEM QTY.
SENSOR 1
TEE, HORIZONTAL 1
TEE, VERTICAL 1
BUSHING 1
SPIGOT 1
NPT BUSHING 1
PLUG 1
WARNING LABEL 1
INSTRUCTIONS 1
* ITEMS REQUIRED FOR ASSEMBLY
- PVC CEMENT
- TEFLON TAPE
3/4" NPT SPIGOT
1" TO 3/4" NPT
SCHEDULE 40
THREADED BUSHING
SCHEDULE 40
PVC BUSHING
1" TO 3/4"
FPS-T SENSOR
WIRE: 6 FEET
SCHEDULE 40
3/4" PLUG
SCHEDULE 40
CUSTOM 1" TO 3/4" TEE
HORIZONTAL IN-LINE
SCHEDULE 40
CUSTOM 1" TO 3/4" TEE
VERTICAL IN-LINE
INSTALLATION INSTRUCTIONS
* REMOVE SENSOR PRIOR TO INSTALLATION
* DO NOT GLUE SENSOR TO HOUSING
* PLUG DRAIN AND FILL PAN TO CONFIRM
SENSOR FUNCTION AFTER INSTALLATION
* REMOVE SENSOR TO CLEAN & INSPECT
.09" ±.10
WATER LEVEL @
SENSOR ACTIVATION
PIPE CENTERLINE
1.68"
2.50"
3.35"
1.06"
2.18"
VERTICAL
INSTALLATION
HORIZONTAL
INSTALLATION
VERTICAL TEE
MARKING
HORIZONTAL TEE
MARKING